Repair instruction

Manual pump adjustment

1. Keep the 1-cup and 2-cup button pressed while connecting the appliance to the mains.
2. The buttons can be released when the 1-cup and 2-cup LEDs are switched on.
You entered automatically the 1-cup pump time adjusting step.

3. 1-cup adjustment:

a. Press and release the 1-cup button to decrease the calibration value.
The 1-cup and 2-cup LEDs blink one time.
b. Press and release the 2-cup button to increase the calibration value.
The 1-cup and 2-cup LEDs blink one time.
4. Store new 1-cup pump time values:
Press and release the 1-cup and 2-cup buttons to store the calibration value.
The 1-cup and 2-cup LEDs blink rapidly 3 times.
You enter automatically the 2-cup pump time adjusting step, 1-cup and 2-cup buttons are on.

5. 2-cup adjustment:

a. Press and release the 1-cup button to decrease the calibration value.
The 1-cup and 2-cup LEDs blink one time.
b. Press and release the 2-cup button to increase the calibration value.
The 1-cup and 2-cup LEDs blink one time.
6. Store new 2-cup values:
Press and release the 1-cup and 2-cup buttons to store the calibration value.
The 1-cup and 2-cup LEDs blink rapidly 3 times.
The 1-cup & 2-cup LEDs will switch off and you exit the justifi cation routine.

Boiler reset

1. Keep the 1-cup button pressed while connecting the appliance to the mains.
2. Button can be released when the 2-cup LED blinks rapidly