VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
2.
Lift fan cover up and out of oven.
Fig. 7
3.
Reverse procedure to install.
CONTROL PANEL COMPONENTS
electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove CONTROL PANEL.
2.
Remove component being replaced.
3.
Reverse procedure to install replacement
component.
4.
Check oven for proper operation.
Disconnect the
Page 7 of 31
Fig. 8
NOTE: Panel with standard controls shown.
COMPONENT PANEL
COMPONENTS
electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE PANEL.
NOTE: If right side panel is not accessible, this
component can be service by removing CONTROL
PANEL.
2.
Disconnect wire leads to component being
replaced.
3.
Remove component.
4.
Reverse procedure to install component.
5.
Check oven for proper operation.
Disconnect the
F45652 (0217)