Section Overview; Safety Messages - Emerson 3051SMV Reference Manual

Multivariable transmitter
Hide thumbs Also See for 3051SMV:
Table of Contents

Advertisement

Reference Manual
00809-0100-4853, Rev AB
Section 2
Flow configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Variable configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Device configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Device capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
Node address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Block instantiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
2.1

Section overview

This section contains information for the flow and device configuration of the Rosemount
MultiVariable
configuration tool has different ways of displaying and performing operations. Some hosts will use
Device Descriptions (DD) and DD methods to complete device configuration and will display data
consistently across platforms.
The DD can be found on the FieldComm Group website at FieldCommGroup.org. There is no
requirement that a host or configuration tool support the features in the DD. For DeltaV
can be found at EasyDeltaV.com. This section will describe how to use the basic methods.
2.2

Safety messages

Instructions and procedures in this section may require special precautions to ensure the safety of the
personnel performing the operations. Information that raises potential safety issues is indicated by a
warning symbol (
Explosions could result in death or serious injury.
Do not remove the transmitter cover in explosive atmospheres when the circuit is live.
Before connecting an Emerson
instruments in the segment are installed in accordance with intrinsically safe or non-incendive field
wiring practices.
Verify the operating atmosphere of the transmitter is consistent with the appropriate hazardous
locations certifications.
Both transmitter covers must be fully engaged to meet flameproof/explosion-proof requirements.
Failure to follow these installation guidelines could result in death or serious injury.
Make sure only qualified personnel perform the installation.
Electrical shock could cause death or serious injury.
If the sensor is installed in a high-voltage environment and a fault or installation error occurs, high
voltage may be present on the transmitter leads and terminals.
Use extreme caution when making contact with the leads and terminals.
Configuration
Configuration
F
Fieldbus Transmitter (3051SMV). Each F
OUNDATION
). Refer to the following safety messages before performing an operation.
Field Communicator in an explosive atmosphere, make sure the
Configuration
January 2017
3051S
Fieldbus host or
OUNDATION
users, the DD
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents