DC/DC Power Supply Installation, Screws on Top of lid

For use with Honeywell power supplies
• 9000301PWRSPLY – Power Supply, 18-60VDC with cable
• 9000302PWRSPLY – Power Supply, 60-110VDC with cable:
Shown With Lid Attached
• Lid is secured with screws on the top of lid.
If your DC to DC power supply does not look like the image above, see
of Lid
(page 14-29) for installation instruction.
Connecting Electrical Cables to Power Sources
The DC to DC power supply is used to provide vehicle power to the MX7 Tecton when placed in a DC powered vehicle
cradle.
Specifications for Electrical Supply
Input Voltage
Output Voltage
Power
Fuse
Note: Refer to the Wiring Schematic that follows for wiring colors and connections.
Caution:
For proper and safe installation, the input power cable must be connected to a fused circuit on the
vehicle. This fused circuit requires a five Amp maximum time delay (slow blow) high interrupting rating
fuse. If the supply connection is made directly to the battery, the fuse should be installed in the positive
lead within 5 inches of the battery positive (+) terminal. Note: For North America, a UL Listed fuse is to
be used.
Caution:
Usage in areas where moisture can affect the power supply connections should be avoided. The power
supply should be mounted in a dry location within the vehicle or placed in a suitable protective
enclosure.
Caution:
For installation by trained service personnel only.
Warning:
Risk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well
ventilated area. Avoid creating arcs and sparks at battery terminals.
14 - 26
Always observe input voltage range specified on the DC to DC power supply.
12 VDC ± 10%
60 W
5 A (slow blow fuse). Fuses are USER SUPPLIED
Shown With Lid Removed
• Input and output connector blocks under lid.
• Two positive (+), negative (-) and ground ( )
connections per terminal block