Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
Register this product at www.greenlee.com
52062054 REV 2
© 2013 Greenlee Textron Inc.
9/13

Advertisement

Table of Contents
loading

Summary of Contents for Greenlee EHP700L

  • Page 1 INSTRUCTION MANUAL EHP700L Battery-powered Pump Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product at www.greenlee.com 52062054 REV 2 © 2013 Greenlee Textron Inc. 9/13...
  • Page 2: Table Of Contents

    Do not discard this product or throw away! For recycling information, go to www.greenlee.com. All specifications are nominal and may change as design improvements occur. Greenlee Textron Inc. shall not be liable for damages resulting from misapplication or misuse of its products. KEEP THIS MANUAL Greenlee / A Textron Company 4455 Boeing Dr.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION SAFETY ALERT Do not connect the pump to any system or system component other than those supplied by Greenlee. SYMBOL Other manufacturers’ components may not with- stand the maximum pressure and may fail. Nearby personnel can be injured by flying components and This symbol is used to call your attention to hazards hydraulic oil.
  • Page 4 Inspect pump, hoses, couplers, and fittings for wear or damage. Replace worn, damaged, or missing com- • Do not expose power tools to rain. ponents with Greenlee replacement parts. Worn or • Do not immerse the pendant switch damaged components can fail, resulting in injury.
  • Page 5: Important Safety Information

    Failure to observe this precaution may result in injury and property damage. Note: Keep all decals clean and legible, and replace when necessary. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 6: Identification

    Maximum Operating Pressure ............10,000 psi (700 bar) Operating Temperature Range ........10 °F to 104 °F (-12°C to 40 °C) Dual-Stage Pumping Action Rapid Advance .....................0.9 l/min At Full Pressure ....................0.3 l/min Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 7: Features Of The Pump

    To change the units, set the selection switch to 7, depress the pendant toggle three times, and then hold the toggle switch to change the display. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 8: Operation

    Inspect pump, hoses, couplers, and fittings for wear Skin injection hazard: or damage. Replace worn, damaged, or missing • Do not use hands to check for components with Greenlee replacement parts. Worn leaks. or damaged components can fail, resulting in injury. • Depressurize hydraulic system...
  • Page 9: Operation

    Note: The retraction button of the forward and return not running. switch is always active and can be actuated at any time and in any program. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 10: Maintenance

    Annually or After 10,000 Cycles remove oil. 1. Replace the hydraulic oil. Failure to observe this warning 2. Send the tool to a Greenlee Authorized Service could result in serious injury, gan- Center for inspection. grene, or death. Checking the Hydraulic Fluid Level The pump has an oil plug with inspection glass, which can be used to determine the proper oil level.
  • Page 11: Troubleshooting

    Air in hydraulic system. Start pump and hold retract button simultaneously. Run for approximately 10 seconds, and then attempt to cut. If unsuccessful, return tool to a Greenlee Authorized Service Center. Cold oil. Start pump and hold retract button simultaneously to warm oil.
  • Page 12: Illustrations And Parts Lists

    EHP700L Battery-powered Pump Illustration—Main Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 13: Motor

    Seal kit (includes items marked with † ) 52062193 Fitting, 90°..........1 52062239 Fastener kit (includes items 52060735 Cover ............1 marked with * ) Screw ............1 Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 14: Release Lever

    T = 1.5 Nm max. Part No. Description 52062196 Release lever unit Release lever.........1 Screw ............1 Compression spring ......1 Bolt............1 Nut ............1 T = 1.5 Nm max. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 15: Pump Housing Unit

    Valve seat ..........1 8† O-ring ............1 † 52062238 Seal kit (includes items marked with † ) 52062239 Fastener kit (includes items marked with * ) Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 16: Relief Valve

    Screw plug ..........1 3† Piston seal ..........1 4† Washer ..........1 Pump piston..........1 Valve stem ..........1 Spring ...........1 † 52062238 Seal kit (includes items marked with † ) Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 17: Reservoir Assembly

    O-ring ............1 Adapter ..........1 Reservoir plate ........1 † 52062238 Seal kit (includes items marked with † ) 52062239 Fastener kit (includes items marked with * ) Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 18: Control Unit

    Screw ............4 Pin ............1 Washer ..........4 Washer ..........2 Standoff ..........4 Standoff ..........2 52062239 Fastener kit (includes items Knob .............1 marked with * ) LCD display ..........1 Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 19 EHP700L Battery-powered Pump Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 20 4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070 USA Tel: 800-435-0786 Canada Tel: 800-435-0786 International Tel: +1-815-397-7070 An ISO 9001 Company • Fax: 800-451-2632 Fax: 800-524-2853 Fax: +1-815-397-9247 Greenlee Textron Inc. is a subsidiary of Textron Inc. www.greenlee.com...