SERVICE MANUAL
H4660B/42190
Submersible Pump
Read and understand all of the instructions and
safety information in this manual before operating
or servicing this tool.
999 1468.9 REV 8
© 2005 Greenlee Textron Inc.
11/05

Advertisement

Table of Contents
loading

Summary of Contents for Greenlee Fairmont H4660B

  • Page 1 SERVICE MANUAL H4660B/42190 Submersible Pump Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 999 1468.9 REV 8 © 2005 Greenlee Textron Inc. 11/05...
  • Page 2: Table Of Contents

    H4660B / 42190 Submersible Pump Purpose This manual is intended to familiarize all personnel with the safe service procedures for the H4660B/42190, serial code FLM Submersible Pump. Keep this manual available to all personnel. Replacement manuals are available upon request at no charge.
  • Page 3: Important Safety Information

    Before operating this tool, see the safety information and operating instructions in the Operation Manual. Greenlee / A Textron Company H4660B / 42190 Submersible Pump Do not operate the pump if the impeller blades are exposed. After assembly, install the inlet screen before operating the pump.
  • Page 4 Hot hydraulic fluid can cause serious burns. Greenlee / A Textron Company H4660B / 42190 Submersible Pump Hydraulic oil can cause skin irritation. • Handle the tool and hoses with care to prevent skin contact with hydraulic oil.
  • Page 5: Disassembly

    (8). Remove external retaining ring (9) from shaft (7) and pull off two bearings (8). Greenlee / A Textron Company H4660B / 42190 Submersible Pump Motor 1. Scribe a line across body (15) and rear cover (12) to align parts correctly during assembly. If body or...
  • Page 6: Inspection

    5. Inspect all other disassembled components for cracks, grooves, or nicks. Greenlee / A Textron Company H4660B / 42190 Submersible Pump Assembly Refer to the Exploded View(s) and Parts List for correct orientation and placement of parts. Replace any O-rings, V-rings, seals, and gaskets on parts that have been disassembled.
  • Page 7 (20) and lock washers (21). Greenlee / A Textron Company H4660B / 42190 Submersible Pump Impeller Clearance 1. Slide shim (12) onto end of shaft (7). Install Woodruff key (11) in keyway of shaft (7). Slide impeller (13) onto shaft, guiding keyway in impeller over the Woodruff key in shaft.
  • Page 8 Exploded View H4660B/42190 Submersible Pump Greenlee / A Textron Company H4660B / 42190 Submersible Pump 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
  • Page 9: Exploded Views And Parts List

    43186 F011339 Repair Kits 40795 132659 Greenlee / A Textron Company H4660B / 42190 Submersible Pump Description H4660B Submersible pump Housing (includes next item) ... 1 Stud, 3/8–16 x 1.50" stainless steel ... 6 Gasket shim, .005" (blue) ... 1 Gasket shim, .010"...
  • Page 10: Accessories

    4455 Boeing Drive • Rockford, IL 61109-2988 • USA • 815-397-7070 An ISO 9001 Company www.greenlee.com 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070 800-435-0786 Fax: 800-451-2632 815-397-7070 Fax: 815-397-1865 800-435-0786 Fax: 800-524-2853 Fax: +1-815-397-9247 Greenlee Textron Inc. is a subsidiary of Textron Inc. • Printed in USA...