Split unit air conditioner
ceiling mounted c series; e series; fl-e series; fh-c series; fly-e series; fhy-c series
cooling only & heatpump [50hz] (78 pages)
Page 1
INSTALLATION MANUAL Split System air conditioners FHB35Fk7V1 FHYB35Fk7V1 FHB45Fk7V1 FHYB45Fk7V1 FHB60Fk7V1 FHYB60Fk7V1 FHYB71Fk7V1 FHYB100Fk7V1 FHYB125Fk7V1...
Page 2
fi ˆ˜ ÚÔÛ‰ÈÔÚ›˙ÂÙ·È ÛÙÔ ∞Ú¯Â›Ô ∆¯ÓÈ΋˜ ∫·Ù·Û΢‹˜ DAIKIN.TCF.004 Î·È ÎÚ›ÓÂÙ·È ıÂÙÈο · fi ÙÔ KEMA Û‡Ìʈӷ Ì ÙÔ ¶ÈÛÙÔ ÔÈËÙÈÎfi 59277-KRQ/ECM95-4233. Nota tal como estabelecido no Ficheiro Técnico de Construção DAIKIN.TCF.004 e com o parecer positivo de KEMA de acordo com o Certificado 59277-KRQ/ECM95-4233. Bemærk som anført i den Tekniske Konstruktionsfil DAIKIN.TCF.004 og positivt vurderet af KEMA i henhold til Certifikat 59277-KRQ/ECM95-4233.
6 pcs. OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY Other: installation and operation manual TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A Screws for fixing panels are attached to the air inlet panel.
2. Use suspension bolts for installation. Check whether the For the following items, take special care during ceiling is strong enough to support the weight of the construction and check after installation is finished indoor unit. If there is a risk, reinforce the ceiling before installing the unit.
• For other installation than standard installation, contact your Daikin dealer for details. • The outdoor unit is charged with refrigerant. 2. The fan speed for this indoor unit is preset to provide •...
• Check the pipe connector for gas leaks NOTE Liquid pipe Gas pipe The drain outlet is only used to discharge water if the drain pump Insulation for fitting of liquid line is not used or before maintenance. Gently put in and out the (supplied with the unit) drain plug.
3 Remote controller cords and wires connecting the units Electrical characteristics should be located at least 50mm away from power supply wiring. Not following this guideline may result in malfunction Model Volts Voltage range due to electrical noise. 4 For the remote controller wiring, refer to the "Installation FH(Y)B35~125 min.198-max.264 manual of the remote controller"...
MAIN/SUB CHANGEOVER IELD ETTING 1. Insert a wedge-head screwdriver into the recess between the Field setting must be made from the remote controller in upper and lower part of the remote controller and, working accordance with the installation condition. from the 2 positions, pry off the upper part. (see figure 13) (The remote controller PC board is attached to the upper part •...