Daikin FH(Y)B35FV1 Operation Manual
Daikin FH(Y)B35FV1 Operation Manual

Daikin FH(Y)B35FV1 Operation Manual

Split system air conditioner
Hide thumbs Also See for FH(Y)B35FV1:

Advertisement

SPLIT SYSTEM

MODELS
(Ceiling-mounted cassette built-in type)
FH(Y)B35FV1
FH(Y)B45FV1
FH(Y)B60FV1
FHYB71FV1
FHYB100FV1
FHYB125FV1

OPERATION MANUAL

FHYB71FVAL
FHYB100FVAL
FHYB125FVAL

Air Conditioner

English
Español
Portugues

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FH(Y)B35FV1

  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Español MODELS (Ceiling-mounted cassette built-in type) Portugues FH(Y)B35FV1 FHYB71FVAL FH(Y)B45FV1 FHYB100FVAL FH(Y)B60FV1 FHYB125FVAL FHYB71FV1 FHYB100FV1 FHYB125FV1...
  • Page 2 Thank you for purchasing this Daikin air condi- tioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference.
  • Page 3 TEST AVAILABLE TEST R35,50 RY35 RY50,60 R(Y)100,125 R(Y)71...
  • Page 4: Table Of Contents

    AND DISPLAY ON THE REMOTE CONTROLLER..........4 NOTE 6. OPERATION PROCEDURE ......5 • Contact your Daikin dealer in case of changing 7. OPTIMUM OPERATION ........ 6 the combination or setting of group control and 8. MAINTENANCE two remote controller control systems.
  • Page 5 Incomplete installation performed by yourself CAUTION ..These are the matters with possi- may result in a water leakage, electric shock, bilities leading to injury or material and fire. damage due to erroneous han- Ask your dealer to move and reinstall the air dling including probabilities lead- conditioner.
  • Page 6: Operation Range

    Do not place a burner or heater at a place 19.4 to 46 20 to 32 directly exposed to the wind from the air con- R35, < R50,R60- ditioner. VIK> Incomplete combustion of the burner or heater COOL- 14 to 23 19.4 to 54 may result.
  • Page 7: Name And Function Of Each Switch And Display On The Remote Controller

    • Do not use the air conditioner in the following 5. NAME AND FUNCTION OF EACH places. SWITCH AND DISPLAY ON THE a. Filled with much mineral oil such as cutting oil b. Where there is much salt such as a beach area REMOTE CONTROLLER c.
  • Page 8: Operation Procedure

    Regarding outside air temperature and heat- • Operating procedure varies with heat pump type ing capacity and cooling only type. Contact your Daikin dealer • The heating capacity of the air conditioner to confirm your system type. declines as the outside air temperature falls. In •...
  • Page 9: Optimum Operation

    • An indoor fan runs to discharge a gentle wind TIMER MODE START/STOP automatically until the temperature inside the air conditioner reaches a certain level. At this time, the remote controller displays “ ”. Leave it Press the TIMER MODE START/STOP button as it stands and wait for a while.
  • Page 10: Maintenance (For Service Personnel)

    • Keep doors and windows closed. If the doors and (Refer to Fig.1) windows remain open, room air will flow out and cause to decrease the effect of cooling and heating. • Do not place other heaters directly below the indoor unit.
  • Page 11: Not Malfunction Of The Air Conditioner

    • Do not expose it to fire, as doing so may result in • To protect the unit, turn on the main power switch burning. at least 6 hours before operation. WHAT TO DO WHEN STOPPING THE SYS- 4. Fix the air filter TEM FOR A LONG PERIOD Align the two hangers and push the air filter up.
  • Page 12: Trouble Shooting

    It is necessary to clean the 10. TROUBLE SHOOTING inside of the indoor unit. Ask your Daikin dealer for details on cleaning the unit. This operation I. If one of the following malfunctions occurs, requires a qualified service person.
  • Page 13 1. If the system does not operate at all. • Check if there is a power failure. Wait until power is restored. If power failure occurs during operation, the system automati- cally restarts immediately after the power sup- ply recovers. •...
  • Page 14: Specifications

    WEIGHT OF INDOOR UNIT WEIGHT OF OUTDOOR UNIT REFRIGERANT MASS OF REFRIGERANT CHARGE COUNTRY OF ORIGIN indoor JAPAN JAPAN JAPAN out- THAILAND THAILAND THAILAND door MANUFACTURER’S NAME DAIKIN DAIKIN DAIKIN indoor INDUSTRIES INDUSTRIES INDUSTRIES LTD. LTD. LTD. DAIKIN DAIKIN DAIKIN out- INDUSTRIES...
  • Page 15 3P170549-1 EM95A019F (0602) HT...