12
17E
The signal from the "Door locked " switch is
present although there is no signal from the
"Door closed" switch.
This error code can only be generated prior to
programme start.
If the power is on, be very careful when
working on the machine.
Try to restart the machine (i.e. reset the error
code) by pressing the Start button quickly.
If the error returns, troubleshoot as follows:
Fig.
1. Undo the card contactor X30 on the programme unit
card A1
25
Error message returns
Fig.
26
The programme unit card A1 is probably defective.
18E
CALCAD 4400 doesn't allow start of selected
program.
Try to restart the machine by a quick press on the
START-button.
• Has payment been done?
• Has the machine been reserved?
22
12. Troubleshooting
No error message
Troubleshoot the door lock
and the cabling for electric
or mechanical short-circuit.
25
X30
Alt.
26
Actuator
Service
Manual
6124
X30
5566 F
5368
6112
438 9152-31/06
05.03