Press the remote controller 5 key 2 times and then press
the Track up key. (Inputting "K")
Press the remote controller 2 key 3 times and then press
the Track up key. (Inputting "C")
Press the remote controller 2 key once and then press
the Track up key. (Inputting "A")
Press the remote controller 7 key 2 times and then press
the Track up key. (Inputting "R")
3. Above procedure clears the security which causes the
unit to go into ALL OFF mode.
4. If wrong codes were entered, the unit goes into the Code
Request mode.
Initializing AUDIO-related value setting (DCERR-
related)
• Ez700SR/Ez900HDS Model
1. Enter ALL OFF (STANDBY) mode.
2. While in the ALL OFF (STANDBY) mode, short-push
key, which re-establishes the AUDIO-related values to the
default values of the Test Mode.
Clearing DC error detection information (EEPROM
data clear)
• Ez700SR/Ez900HDS Model
1. While pressing down on Preset e and Preset y keys,
reset to enter the DC Error Display mode. (The Test Mode
is cleared at this point.)
SIRIUS Channel Lock Clear
If the code for clearing the locked channel was lost (when los-
ing track of the code), the default code (0000) can be retrieved
by pressing the reset button.
It must be noted, however, the above procedure would clear
any skip/lock that has been set.
16
TEST MODE
2. In the ALL OFF mode display, the current DC error condi-
tions are displayed.
3. The detected error information can be cleared by long-
push on the [AUD] key, while the error information is be-
ing displayed. (EPROM clear)
4. DC Error Display mode can be cleared by resetting. (The
condition prior to power OFF is not retained.)
Sirius Function Lock Release mode
• Ez700SR/Ez900HDS Model
1. While pressing down on Preset t and Disp keys, reset
to enter the DC Error Display mode. (The Test Mode is
cleared at this point.)
2. If Sirius is prior to FA, the source switching is restricted.
In case of evaluations, however, restrictions would cause
the evaluations to be ineffective. In the HDRadio Test
Mode, therefore, source switching is possible as with the
normal operation.
Prior to Sirius FA : Only "STANDBY" and "SIRIUS" can be
selected as sources.
3. The initial value of the volume will be 30. The specifica-
tion is such that this value is retained even after turning
power ON/OFF.
4. This mode is cleared by resetting. (The condition prior to
power OFF is not retained.)

SIRIUS TEST MODE

Error detected : "DC ERROR"
Error not detected : "DC OK"