Mounting and installation

2

Dimension drawings of the PM230

2
2.1
2.2
1
2
31
5
32
35
36
50
9
51
52
6
53
10
11
26
27
7
1
2
3
3
4
4
12
13
9
21
22
18
DO 0 NC
18
14
19
15
DO 0 NO
19
9
20
20
DO 0 COM
28
8
69
5
23
6
DO 2 NC
23
7
24
DO 2 NO
24
8
25
25
DO 2 COM
16
10
17
Connector for the
RS485 interface
1
5
11
Pin
Pin
1
1
0 V, reference potential
2
2
RS485P, receive and send (+)
3
3
RS485N, receive and send (-)
4
5
4
Cable shield
5
Not connected
6
7
8
9
8
Siemens AG
Mounting and installation
Dimension drawings of the PM230
You can find the dimension drawings in the enclosed document, "Getting Started
SINAMICS PM230".

Structure of the Control Unit

10
31 +24V IN
32 GND IN
-
35 +10V OUT
36 GND
50
AI 2+/NI1000
51 GND
52
AI 3+/NI1000
53 GND
-
-
-
-
10 AI 1+
11 AI 1-
26 AO 1+
27 GND
1
+10V OUT
2
GND
3
AI 0+
4
AI 0-
12 AO 0+
13 GND
21 DO 1 NO
22 DO 1 COM
14 T1 MOTOR
15 T2 MOTOR
9
+24V OUT
28 GND
69 DI COM
5
DI 0
6
DI 1
7
DI 2
8
DI 3
16 DI 4
17
DI 5
SUB-D connector for
CANopen
1
5
11
6
9
Not assigned
CAN_L, CAN signal (dominant low)
CAN_GND, CAN ground
Not assigned
(CAN _SHLD), optional shield
(GND), optional ground
CAN_H, CAN signal (dominant high)
Not assigned
Not assigned
1
Memory card slot (MMC or SD card)
2
Interface for an operator panel (IOP or BOP-2)
3
USB interface for STARTER
Status LED
4
DIP switch for fieldbus address
5
(
for PROFINET no function
Bit 6 (64)
Bit 5 (32)
Bit 4 (16)
Bit 3 (8)
Bit 2 (4)
Bit 1 (2)
Bit 0 (1)
On
Off
6
LG-NI1000 DIP switch AI2
(
terminals 50 51
DIP switch for AI0
AI1
and AI1 (terminals
AI0
3/4 and 10/11)
Current
Voltage
8
Digital outputs
9
Terminal strip
10
Terminal designation
11
Switch for bus terminating resistor
RJ45 connector socket
for PROFINET IO
1
8
Pin
Pin
1
1
RX+, receive data +
2
2
RX-, receive data -
3
3
TX+. Transmit data +
4
Not assigned
5
Not assigned
4
6
TX-, transmit data -
5
7
Not assigned
8
Not assigned
6
7
8
9
RDY
BF
---
LNK1, nur bei PROFINET
LNK2, nur bei PROFINET
)
Example:
8
2
Address = 10
/
)
SUB-D socket for
PROFIBUS DP
5
1
9
6
Shield, ground connection
Not assigned
RxD/TxD-P, receive and send (B/B')
CNTR-P, control signal
DGND, reference potential for data
(C/C')
VP, supply voltage
Not assigned
RxD/TxD-N, receive and send (A/A')
Not assigned