10.
Service - Programm
10.2
Fault indication in the multidisplay.
Machines without multidisplay show the faultcodes with the program cycle LED's.
In this case you have to take care about the values of the single LED's.
If fault E40 is shown the LED mainwash will be blinking.
If faultcode E93 is shown, Prewash, Rinse+, End und Overdosage blinks.
The faultcode contents following values:
LED
Prewash
Rinse+
Total
End
Overdosage
Total
Now you are able to figure out the faultcodes in the previous tables.
TSE-N 01.2000 R.K.
LED Off
LED On
Value
8
1
9
2
1
3
- 30 -