Factory Defaults Button; Power Supply Units - NETGEAR ProSAFE M4300 series Installation Manual

Managed stackable switch
Hide thumbs Also See for ProSAFE M4300 series:
Table of Contents

Advertisement

interface on model M4300-52G-POE+ provides a receptacle for an RPS cable such as the NETGEAR DC
Connection Cable Model RPSC5412.

Factory Defaults Button

The switch provides a Factory Defaults button on the front panel so that you can return the switch to its
factory settings.
To return the switch to its factory default settings:
1.
Insert a device such as a straightened paper clip into the opening.
2.
Press the recessed Factory Defaults button for about three seconds. The switch reboots and returns
to its factory settings.

Power Supply Units

The following table describes the power supply units (PSUs) and options. For model M4300-28G-POE+
and model M4300-52G-POE+, the PSU that is installed depends on the product ordered. For models that
can support two PSUs, you can order a second PSU as an option.
Table 4. Supported PSUs
Switch Model
M4300-8X8F
M4300-12X12F
M4300-24X24F
M4300-28G
M4300-52G
M4300-28G-POE+
Managed Stackable Switch Series M4300
Possible PSU Configurations
1x APS250W
1x APS250W
1x APS250W2x
APS250W
1x APS250W2x
APS250W
1x APS250W2x
APS250W
1x APS550W
2xAPS550W
1x APS1001x
2x APS1000W
1x APS550W + 1x APS1000W
(see Note)
Hardware Overview
Power Redundancy
N+1 redundancy
33
RPS Support

Hide quick links:

Advertisement

Table of Contents
loading