Code
6100
Broken fuser heater lamp 2 wire
The detected fuser thermistor 2 temper-
ature does not rise 1
fuser heater lamp 2 has been turned on
continuously for 5 seconds in warming
up.
The detected temperature of fuser
thermistor 1 does not reach 80
after fuser heater lamp 2 has been
turned on continuously for 40 seconds in
warming up.
The detected temperature of fuser
thermistor 1 does not rise 1
after fuser heater lamp 2 has been
turned on continuously for 5 seconds
thermistor 1 is 100
istor 2 continuously for 3 seconds.
6120
The fuser thermistor 1 detects a temper-
more) of fuser thermistor 2, the illumina-
tion of fuser heater lamp 2 was forcibly
turned off and 10 seconds has elapsed.
Contents
C/1.8
F after the
C/176
F
C/1.8
F
C/180
F lower than
C/464
F.
C/446
F or
Causes
Check procedures/corrective measures
Defective harness
Reinsert the connector. Also check for conti-
between fuser
nuity within the connector harness. If none,
thermistor 1 and
remedy or replace the harness.
paper exit PWB
(YC4), or improper
connector inser-
tion.
Defective harness
Reinsert the connector. Also check for conti-
between paper exit
nuity within the connector harness. If none,
PWB (YC1) and
remedy or replace the harness.
(YC602), or
Replace the fuser unit (See page 1-5-24).
installed incor-
rectly.
Fuser thermal cut-
Replace the fuser unit (See page 1-5-24).
out triggered.
Fuser heater lamp
Replace the fuser unit (See page 1-5-24).
2 installed incor-
rectly.
Broken fuser
Replace the fuser unit (See page 1-5-24).
heater lamp 2 wire.
Replace the engine PWB (See page 1-5-
28).
Replace the fuser unit (See page 1-5-24).
Replace the engine PWB (See page 1-5-
28).