Ice Maker Troubleshooting Chart
Problem
Shut-off arm not in actuator
Deformed shut-off arm
Broken shut-off lever or
lever bypassing vertical cam
Broken module actuator
Problem
Low water fill volume
Improper freezer air-flow
Thermostat out of calibration
Problem
Thermostat out of calibration
Jammed cube stalled in water-fill cycle
Leaky water valve
Excessive water fill volume
Motor stalled in water-fill cycle
(12:00 ejector position)
Contaminated module
Refrigerator or ice maker not level
Excessive water pressure
Shorted and burned module shut-off
switch and contacts
Broken locking tab on verticle cam
(Stalled in water fill)
Fill-tube not properly positioned in
fill cup
Fill cup water opening blocked
Cubes fall over back of ice maker,
melting in freezer
February 1998
Excessive Ice Production
Action
Replace shut-off arm in actuator
Replace shut-off arm
Replace module
Replace module
Hollow Ice Cubes
Action
Adjust module screw, clear water path,
or replace water valve
Direct air flow away from thermostat
Replace thermostat
Apply alumilastic
Flooding or Ice in Bucket or Freezer
Action
Replace thermostat
Apply alumilastic
Remove cube
Determine reason for stall
Replace water valve
Replace water valve
Replace module
Replace module
Level refrigerator or ice maker
Decrease water pressure (20-120 psi) (1.4 - 8.2 bar)
Replace module
Replace module
Reposition fill tube
Replace fill cup
Replace fill cup