Horizontal Scanning; Vertical Scanning; Power Input Connection; Power Management - Philips 192E2SB2/10 Service Manual

18.5 inch wxga tft lcd colour monitor
Table of Contents

Advertisement

3.4

Horizontal scanning

Sync polarity
Scanning frequency
3.5

Vertical scanning

Sync polarity
Scanning frequency
3.6

Power input connection

Power cord length
Power cord type
3.7

Power management

The monitor must comply with the Microsoft On Now specification, and meet EPA requirements.
HSYN
Mode
Power-On
On
Standby
Off
DC Power Off
3.8

VGA Display identification

In accordance with VESA Display Channel Standard Ver.1.0 and DDC 2B capability
3.9

DVI Display identification

In accordance with DVI requirement (DDWG digital Visual Interface revision 1.0)
use DDC-2B, DDC/CI, and EDID V1.3

3.10 USB support

Connect the upstream port of the monitor to host PC's USB port via USB cable. Then attach
external device to the downstream port of the monitor. Check if the device can work properly.

3.11 DDC /CI Support and Smart Manage/Control

In accordance with VESA DDC/CI and MCCS ver.2.0, the monitor should be workable with ,
Philps SmartManage, SmartControl V6.1, and Protrait Display Tune at least.
2010/08/19
General Product Specification
: Positive or Negative
: 30 – 83 K Hz
: Positive or Negative
: 56 - 76 Hz
: 1.8 M
: 3 leads power cord with protective earth plug.
VSYNC
Video
C
On
Active
Off
Blanked
N/A
192E2SB2
PHILIPS
Pwr-cons.
Indication
< 25W(max.)
White LED
Blinking white LED
< 0.5W
Period 1sec on
< 0.5W
18.5" Wide WXGA LCD Monitor
192E2SB2 LCD
Rec. time
< 3 s
3sec off
LED Off
11 of 26
63
--

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents