24
System Specifications - 110 VAC and 220 VAC Wiring
Circuit Protection: Two-pole 20 AMP device at the electrical panel.
IntelliChlor Model IC20
Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).
Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.
Chlorine: 0.70 lb. / 24 hour. (317 gm / 24 Hour).
Water flow: 15 gallons per minute minimum. 105 gallons per minute maximum. Maximum pressure: 75 psi
IntelliChlor Model IC40
Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).
Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.
Chlorine: 1.40 lb. / 24 Hour (635 gm / 24 Hour).
Water flow: 15 gallons per minute minimum. 105 gallons per minute maximum. Maximum pressure: 75 psi.
IMPORTANT: When using IntelliChlor with an IntelliTouch system, it is recommended to wire
the Power Center to the pump side of the relay located in the IntelliTouch Load Center. This
method does not require a ground fault circuit-interrupter (GFCI) to protect the circuit.
IntelliChlor Installation and User's Guide

220 VAC Basic System Wiring

110 VAC Basic System Wiring