14 B+ voltages table
TOP PREVIOUS NEXT
Preparation:
Set the following controls
Picture to Normal
Bright to Normal
Volume to MIN (0)
Procedure:
1. Apply a COLOR BAR pattern
2. Connect the negative lead of the digital voltmeter to TPGND1 (cold ground).
3. Connect the positive lead of the digital voltmeter to each test point and confirm the B+ voltages.
TOP PREVIOUS NEXT
http://tsn.pstc.panasonic.com/viewing/NA/PT-53X54J/SVC/s1400000000x.html [23/04/2012 12:16:17 p.m.]
No.
D-Board Test
Voltage
point
1
TPD14
138.6±1.0
2
TPD13
20.0±1.5
3
TPD12
19.5±1.5
4
TPD11
-20.5±1.5
5
TPD10
22.5±1.5
6
C845 (-)
-22.5±1.5
No. A-Board Test point
Voltage
1
TP41
9.0±0.5
2
TP44
5.0±0.5
3
TP39
3.3±0.3
4
TP54
2.5±0.25
5
TP55
1.8±0.5