Standard Operation Chart - Yamaha CDX-396 Manual

2hz-20khz
Hide thumbs Also See for CDX-396:
Table of Contents

Advertisement

CDX-396/496
Pick-up Head
Sled Shaft
Stopper

STANDARD OPERATION CHART

POWER ON
Press OPEN/CLOSE key.
Forced feed return operation
Clamp down operation
Tray open
Load a disc.
Press PLAY key or push the tray.
Tray closed
Disc mechanism unit clamped up.
Feed inward switch reached.
Tracking offset auto ADJ
Laser ON
Focus offset auto ADJ
Disc scan
Focus gain rough ADJ
Focus search operation
Focus lock servo ON
Spindle motor accelerated.
Tracking servo ON
Spindle servo ON
VCO lock
Feed servo ON
A
7
Gear A
Check that the disc table height is as specified below.
19.4 ± 0.2mm
Fig. 5
If a disc is not loaded, "0:00" appears in the time indicator.
"
" appears in the TIME indicator.
OPEN
"TRV" signal is output until detection of LIMIT switch.
Stop after detection of LOADING switch.
Proceeds to next step after detection of LOADING switch.
if FLSW = L (IC300, 23 pin)
Proceeds To Next Step.
LDON = H (IC1, 5 pin)
FLOCK = H → L (IC300, 18 pin)
TLOCK = H → L (IC300, 19 pin)
Disc Table