11.8
Climatic conditions
Operation
Temperature range
Temperature gradient
Relative humidity
Air pressure
Transport and storage (packed)
Temperature range
Temperature gradient
Relative humidity
Air pressure
11.9
Mechanical requirements
Operation
Vibration
Shock
Packed unit (original packaging)
Vibration
Shock
Dropping when packed
SMD 18101 CS / SMD 18101 CP / SMD 18101 D
Instruction Manual, 11/2005, A5E00472377A-002
11.8 Climatic conditions
5°C ... 35°C ambient temperature
Max. 5 °C/h, no condensation
10% ... 80% at 25°C
700 ... 1050 hPa
-20 °C ... +60 °C ambient temperature
Max. 5 °C/h, no condensation
10% ... 90% at 25°C
674 ... 1050 hPa
To EN 60068-2-6
10 ... 58 Hz at ± 0.075 mm deflection
58 ... 500 Hz at 10 m/s²
To EN 60068-2-29
150 m/s², 6 ms
To EN 60068-2-6
5 ... 9 Hz at ± 3.5 mm deflection
9 ... 500 Hz at 10 m/s²
To EN 60068-2-29
250 m/s², 6 ms (in storage packaging)
To EN 24180-2
Drop height: 80 cm
Technical data
11-5