TCXO UNIT (50·2)
1
Remove the transceiver bottom cover (9 screws).
i
1
1
t
: ,
0...
!~'
. '
~_l
.... _.,
'--'"""' ••
'~'
.0.
.3
<
~ft'~
2
Remove the shield covering the control board (2
screws).
3
CAREFULLY remove the 3 flat cables from the
control board, and lift the board.
4
CAREFULLY remove the 3 coaxial cable
connectors (CN2, CN3, CN4) and the 4-pin
connector (CN1) from the PLL board. Do not pull
on the wires to remove CNI. Remove the 8
screws holding the PLL board.
I
I
I
I
I
l
i-t~---~t--r--~--
gD)~
,
'
,
I
--~
,
10 OPTIONS INSTALLATION
5
Lift the PLL board.
6
Position and solder the SO-2. Use a low power
iron (25W) and rosin core solder. Do not overheat
the PC board and lift foil traces, and do not use
excess solder and cause a solder bridge (short).
Clip the SO-2 leads flush to the PC board after
soldering.
7
Cut the jumper wires at WI and W2 on the PLL
board.
S
Re-position the PLL board.
9
Tighten the 8 screws to secure the PLL board.
Reconnect the 3 coaxial cable connectors (CN2,
CN3, CN4) and the 4-pin connector (CN1).
10 Reinstall the control board and CAREFULLY
reconnect the flat cables.
11 Reinstall the shield using the 2 screws.
12
Reinstall the bottom cover (9 screws).
Note:
Do not pinch
your
fingers
nor any
wires while
reassembling.