MAINTENANCE
Service Data
Replace the hydraulic oil regularly!
¡ When using a hydraulic breaker, the oil
deteriorates quicker than during normal
digging. Be sure to replace the hydraulic
oil and return filter element.
• Failure to replace these in time can lead
to damage to the machine and breaker's
hydraulic systems. In order to improve
the service life of the hydraulic systems,
be sure to replace the hydraulic oil and
return filter element according to the
following chart of the replacement
interval.
• Clean the suction strainer when
changing the return filter element.
Expendables
Replace expendables such as filters and elements periodically, referring to the table below.
Item
Hydraulic oil return
filter
Fuel filter
Engine oil filter
Air cleaner
Part name
Element
Element
Cartridge
Element
(outer)
Inner Element
(option)
99
Replacement Interval (Hours)
Item
Hydraulic Oil Filter Element
1st time
2nd time
Periodically
When the breaker operating ratio is 100%
Refer to page 192 "Hydraulic Breaker".
Part No.
15511-01300
< TB014 >
RA211-51281
< TB016 >
119810-55650
< TB014 >
15852-32431
< TB016 >
129150-35151
< TB014 >
1G659-11221
< TB016 >
119515-12520
19111-01342
25
100
600
200
Replacement interval
After first 50 hrs.
Every 500 hrs.
Every 500 hrs.
After first 50 hrs.
Every 250 hrs.
Every 1000 hrs. or
after 6 cleanings
(whichever comes
first)
Every 1000 hrs. or
after 3 cleanings of
the outer element
(whichever comes
first)