Test Mode; Engineering Mode; Base Unit - Panasonic KX-TGE210B Service Manual

Digital cordless phone digital cordless answering system
Hide thumbs Also See for KX-TGE210B:
Table of Contents

Advertisement

KX-TGE210/KX-TGE212/KX-TGE232/KX-TGE233/KX-TGE234/TGEA20

8 Test Mode

8.1.

Engineering Mode

8.1.1.

Base Unit

Important:
Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit.
Make sure the link between Base and Handset before that. Then in case using not original Handset,
you need to deregister Handset.
Note: Refer to Registering a Handset to a Base Unit in the Operating Instructions.
1). Press
2). Select "Settings" using
3). Enter "7", "2", "6", "2", "7", "6", "6", "4".
4). Select "Write EEP" using
5). Enter " ", " ", " ", " " (Address). (*1)
6). Enter " ", " " (New Data). (*1)
Dial keypad
H/S key operation
{
}
MENU
.
{^}
{
}
{>}
then press
SELECT
or
Select "Set tel line" using
{
}
{>}
then press
SELECT
or
Note: 7262 7664 = PANA SONI
(see letters printed on dial keys)
{^} {V}
{
}
{>}
then press
SELECT
or
{OFF}
{FLASH}
{CALL WAIT}
{V}
or
.
{^} {V}
or
.
or
.
26
This pictured model is KX-TGE230.
H/S LCD
Service Mode
Read EEP
Write EEP
BACK
SELECT
Set Addr.:
Default Data
CLEAR
OK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tge212bKx-tge234bKx-tgea20bKx-tge232bKx-tge233b

Table of Contents