Toshiba VF-S15 Instruction Manual page 65

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

3.2.2
How to set the frequency
[Example of fmod setting procedure] fmod=1: Setting the frequency by the terminal VIA
Panel operation
LED display
MODE
auh
fmod
1fmod
*
Pressing the MODE key twice returns the display to standard monitor mode (displaying output frequency).
(1) Setting using the keypad (fmod=0 or 3)
: Moves the frequency up
 Example of operating from the panel (=: press in center to save)
Panel operation
 Example of operating from the panel (=: save even if power is off)
Panel operation
-
Displays the output frequency (operation stopped).
00
(When standard monitor display selection f710=0 [output frequency])
Displays the first basic parameter [History (auh)].
Turn the setting dial, and select "fmod".
Press the center of the setting dial to read the parameter value.
0
(Standard default: 0).
Turn the setting dial to change the parameter value to  (terminal block
1
VIA).
The parameter value is written. fmod and the parameter value are
displayed alternately several times.
LED display
Displays the output frequency.

(When standard monitor display selection = [output frequency])
Set the output frequency. (The frequency will not be saved if the

power is turned off in this state.)
Save the output frequency.  and the frequency are displayed

alternately.
LED display
Display the output frequency.
(When standard monitor display selection is set as =

[output frequency])
Set the output frequency.

The frequency will be saved when the power is turned off in this

state.
C-7
Operation
: Moves the frequency down
Operation
Operation
E6581611
3