 Table of input terminal functions 2
Function
Code
No.
52
IDC
PID integral/differential clear
53
IDCN
Inversion of PID integral/differential clear
54
DR
PID characteristics switching
55
DRN
Inversion of PID characteristics switching
56
FORCE
Forced run operation
57
FORCEN
Inversion of forced run operation
58
FIRE
Fire speed operation
59
FIREN
Inversion of fire speed operation
60
DWELL
Acceleration/deceleration suspend signal
61
DWELLN
Inversion of acceleration/deceleration
suspend signal
62
KEB
Power failure synchronized signal
63
KEBN
Inversion of power failure synchronized signal
64, 65
Factory specific coefficient
70, 71
Factory specific coefficient
74
CKWH
Integrating wattmeter(kWh) display clear
75
CKWHN
Inversion of integrating wattmeter display clear
76
TRACE
Trace back trigger signal
77
TRACEN
Inversion of trace back trigger signal
78
HSLL
Light-load high-speed operation prohibitive
signal
79
HSLLN
Inversion of light-load high-speed operation
prohibitive signal
80
HDRY
Holding of RY-RC terminal output
81
HDRYN
Inversion of holding of RY-RC terminal output
82
HDOUT
Holding of OUT-NO terminal output
83
HDOUTN
Inversion of holding of OUT-NO terminal output
88
UP
Frequency UP
89
UPN
Inversion of frequency UP
90
DWN
Frequency DOWN
91
DWNN
Inversion of frequency DOWN
92
CLR
Clear frequency UP/DOWN
93
CLRN
Inversion of clear frequency UP/DOWN
96
FRR
Coast stop command
97
FRRN
Inversion of coast stop command
98
FR
Forward/reverse selection
99
FRN
Inversion of forward/reverse selection
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Function
ON: Integral/differential clear, OFF: Clear canceled
Inversion of IDC
ON: Inverted characteristics of  selection
OFF: Characteristics of  selection
Inversion of DR
ON: Forced run operation if specified faults are occurred
( frequency)
OFF: Normal operation
Inversion of FORCE
ON: Fire speed operation ( frequency)
OFF: Normal operation
Inversion of FIRE
ON: Acceleration/deceleration suspend
OFF: Normal operation
Inversion of DWELL
ON: Deceleration stop with synchronizing when power failure
OFF: Normal operation
Inversion of KEB
ON: Integrating wattmeter(kwh) monitor display clear
OFF: Disabled
Inversion of CKWH
ON: Trigger(start) signal of trace function
OFF: Disabled
Inversion of TRACE
ON: Light-load high-speed operation prohibited
OFF: Light-load high-speed operation permitted
Inversion of HSLL
ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real time according to
Inversion of HDRY
ON: Once turned on, OUT-NO are held on.
OFF: The status of OUT-NO changes in real time according
Inversion of HDOUT
ON: Frequency increased
OFF: Frequency increase canceled
Inversion of UP
ON: Frequency decreased
OFF: Frequency decrease canceled
Inversion of DWN
OFF
Inversion of CLR
ON: Coast stop (Gate OFF)
OFF: Coast stop canceled
Inversion of FRR
ON: Forward operation command
OFF: Reverse operation command
Inversion of FR
K-31
Action
-
-
conditions.
to conditions.
ON: Clear frequency UP/DOWN
E6581611
Reference
6.24
6.30
6.23
6.19.2
*1
*1
6.36
6.35
6.21
7.2.2
6.10.4
11
3.1.1
6.34.8
7.2.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents