Limitations for one way piping length and vertical height difference

One way piping length ( )
Outdoor
unit is lower
Vertical height
difference (h)
Outdoor
unit is higher

Installation of indoor unit

Installation of installation board

<SRK05, 09CR / SRK05, 09CRP>
Look for the inside wall structures (Intersediate support or pillar
and  raly install the unit after level surface has been checked.)
Mating mark for level surface
• Adjustment of the installation board in the horizontal
direction is to be conducted with  ve screws in a
temporary tightened state.
Standard hole
• Adjust so that board will be level by turning the
board with the standard hole as the center.
<SRK09CRR / SRK12CR>
Look for the inside wall structures (Intersediate support or pillar
and  raly install the unit after level surface has been checked.)
Mating mark for level surface
• Adjustment of the installation board in the horizontal
direction is to be conducted with  ve screws in a
temporary tightened state.
Standard hole
• Adjust so that board will be level by turning the
board with the standard hole as the center.
RMA012A080_091-093_EN.indb 29
15 m
5 m
5 m
250
394
INSTALLATION SPACE (INDOOR UNIT)
Indoor unit
Space for
service
100
155.4
181.9
250
44
Drain hose 386.3 (
Piping for Gas 398.2
Piping for Liquid 455.9
Piping hole (
* Leave extra space on the right side to enable removal of the lid screw.
INSTALLATION SPACE (INDOOR UNIT)
Space for
Indoor unit
service
50
Installation board
187.5
394
157
455
130.5
508
55
Piping for Liquid 449
Piping hole (
65)
Drain hose 530 (
Ø
* Leave extra space on the right side to enable removal of the lid screw.
– 29 –

-
-
(FRONT VIEW)
Unit : mm
Installation board
Space for
service
100
155.4
181.9
44
16)
Ø
65)
Ø
Piping hole (
65)
Ø
(FRONT VIEW)
Unit : mm
Space for
service
100
187.5
157
130.5
55
Piping for Gas 409
16)
Piping hole (
65)
Ø
Ø
05/11/2014 11:50:41