(2) Unit ON/OFF button

When the remote control batteries become weak, or if the remote control is lost or malfunctioning, this button may be used to
turn the unit on and off.
(a) Operation
Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by sen-
sor), whether to go into COOL or DRY modes.
Function
Room temperature
setting
Operation mode
About ºC
COOL
About ºC
DRY

(3) Auto restart function

(a) Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power
cut, and then automatically resumes operations after the power has been restored.
(b) The following settings will be cancelled:
(i) Timer settings
(ii) HIGH POWER operations
Notes () Auto restart function is set at on when the air-conditioner is shipped
from the factory. Consult with your dealer if this function needs to be
switched off.
() When power failure ocurrs, the timer setting is cancelled. Once power is
resumed, reset the timer.
() If the jumper wire (J0) "AUTO RESTART" is cut, auto restart is disa-
bled. (See the diagram at right)

(4) Custom cord switching procedure

If two wireless remote control are installed in one room, in order to prevent wrong
operation due to mixed signals, please modify the printed circuit board in the in-
door unit's control box and the remote control using the following procedure.
Be sure to modify both boards. If only one board is modified, receiving (and
operation) cannot be done.
(a) Modifying the indoor unit's printed circuit board
Take out the printed circuit board from the control box and cut off jumper
wire (J00) using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the
other the lead wires, etc.
(b) Modifying the wireless remote control
(i) Remove the battery.
(ii) Cut the jumper wire shown in the figure at right.
Fan speed
Flap
Timer switch
Auto
Auto
Continuous

-
-
Jumper wire (J201)
Jumper wire (J200)