2. INDOOR UNIT INSTALLATION
2- 1. ATTACHING THE INSTALLATION PLATE
Find a stud in the wall to attach installation plate (1) horizontally on the wall with screws (2).
*
To prevent installation plate (1) from vibrating, be sure to install the attachment screws in
the holes indicated in the illustration. For added support, additional screws may also be
installed in other holes.
«
When
the indoor unit is to be attached to a concrete wall using recessed
bolts, secure
installation plate (1) using 7/16 in. x 13/16 in - 7/16 in. x 4 in. (44 mm
* 20 mm - 14 mm
x
26 mm) oval hole (17-3/4 in. [450 mm] pitch).
*
Ifthe recessed bolt is too long, change it for a shorter one (field-supplied).
2-2. DRILLING
1) Determine where the holes will be located on the wall.
2) Drill a @ 2-9/16 in. (65 mm) hole. The outdoor side should be 6/32 to 9/32 in. (6 te 7 mm)
lower than the indoor side.
3) Insert wall hole sleeve (C).
2-3. CONNECTING WIRES FOR INDOOR UNIT
Note:
When the indoor unit is powered from the outdoor unit, depending on local code, a discon-
nect switch needs to be installed to a power supply circuit.
Remove the panel assembly. (Refer to 5-1.)
Place the upper part of the indoor unit on the installation plate.
Remove corner box and conduit cover.
Attach conduit pipe (for rear piping) / elbow joint (for right, left, or downward
piping) to
conduit cover with lock nut. The thread of the installed conduit pipe / elbow joint appear-
ing inside should
be less than 3/8 in. (10 mm).
(Fig. 1) Elbow joint should appear less
than 1-3/16 in. (30 mm) outside. (Fig. 2)
5) Process
the end of ground wire (Fig. 3). Connect it to the ground terminal of electrical
parts box.
6) Process
the end
of indoor/outdoor
unit connecting
wire (A) (Fig. 3). Attach
it to the
terminal block. Be careful not to make
mis-wiring. Attach the wire to the terminal block
securely so that its core cannot be seen, and
no external force affects the connecting
section of the terminal block.
7) Firmly tighten the terminal screws. After tightening, verify that the wires are tightly fas-
tened.
8) Secure indoor/outdoor unit connecting wire (A) and the ground wire with conduit cover.
Never fail to hook the claw of the conduit cover to the electrical box. Attach the conduit
cover securely. (Fig. 4)
9) According to the piping direction, remove the shaded
part of the left side of box (Fig. 5)
or corner box (Fig.6). Reinstall corner box and front panel.
4)
2)
3)
4)
Remark:
INDOOR UNIT
A disconnect switch is
-
Grouding
required.
Terminal block JJ
terminal**
Check the local code.
** Use a ring tongue termi-
isilsas3
t
nal in order to connect a
:
ground wire to terminal.
_- Disconnect
switch*
208/230 V AC
tphase, 60 Hz
OUTDOOR UNIT
Power supply
208/230 V AC,
iphase 2wires.
60 Hz
Grouding terminal**
Z
SILLETTTE,
Celling
Bind the line to the center hole.
Level
Installation plate (1)
3-5/16 in.
(84 mm)
or more
5-5/8 In. (60 mm) or more
2-3/8 in. (142.5 mm) or more for left
and left back piping (using spacer)
'$518 in (60 mn) or more
3-5/16 in.
(84 mm)
or more
Insert
:
Attachment screw (2)
on een
the
Align tne
cone on
mare?
©
¢ | scale.
the line. *
(65 mm) hole
Plumb
* Same for left hole.
Wall
@ 2-9/16 in.
T4g
(65 mm)
i
6/32-9/32 in.
y
(5-7 mm)
Outdoor side
Lock nut
C J
I 4
____.
Conduit
Fixing
/
cover
indoor terminal
screw
9
|
block
Conduit pipe
fi.
Elbow joint
(for rear piping)
(for right. left, or downward piping)
Connect wires to the appropriate terminals
For future servicing, leave some slack in the connecting wires.
Conduit cover
Less than 3/8 in.
(10 mm)
Lock nut
Conduit pipe or
elbow joint
Less than 1-3/16 in.
(30 mm)
Elbow joint
(for right, left. or
downward piping)
Fig. 2
Fig. 1
|
19/32 in.
Tin.
(15 mm)
(25 mm)
Lead a
wire
Make
ground
wire a
little longer than
others. (More than 1-9/16 in. [40 mm])
Fig. 3
Hook
Conduit cover
Fig. 4
Remove panel for
piping on left side of
unit
Remove panel for
piping on bottom left
side of unit
Fig. 5
Remove panel for
piping on bottom side
of unit
Corner box
tin.
| tes
mm)
Remove panel for
piping on right side of
unit
Fig. 6

Advertisement

Table of Contents
loading

Table of Contents