Electrical Box Temperature Rise - Daikin FTKS20D3VMW Service Manual

Super multi nx
Table of Contents

Advertisement

SiENBE12-713

5.22 Electrical Box Temperature Rise

L3
Remote Control
Display
Outdoor Unit LED
A
Display
Method of
An electrical box temperature rise is detected by checking the radiation fin thermistor with the
Malfunction
compressor off.
Detection
" With the compressor off, the radiation fin temperature is above 100°C.
Malfunction
" The error is cleared when the temperature drops below 70°C.
Decision
Conditions
" Fin temperature rise due to defective outdoor unit fan
Supposed
" Fin temperature rise due to short-circuit
Causes
" Fin thermistor defective
" Connector in poor contact
" Outdoor unit PCB defective
Service Diagnosis
5
1
4
2
4
3
1
4
4
Troubleshooting
265