Accessories
The components in Figures 17 - 19are included in the extra
parts bag supplied with the purchase of *TC/*TLfurnaces.
Depending on your particular installation, some of these
components are optional and may not be used. Please
refer to the descriptions and accompanying figures when
installing these items.
Finish Flange_
The finish flange must be installed to vent the combustion
air pipe through the top of the furnace. NOTE: For proper
installation it is important that the pipe and screw holes
in the finish flange, gasket, and cabinet are aligned. See
Figure 17.
1. Positionflangegasketoverholeinthefurnacecabinet.
2. Position finish flange on top of the flange gasket.
3. Secure flange and gasket to cabinet with three field
supplied sheet metal screws.
Rubber Grommets
The 2 1/4" rubber grommet is used to seal the opening
between the furnace cabinet and the 2" PVC vent pipe.
The rubber grommet should be installed in the 3" hole
prior to running the vent pipe out of cabinet. No sealants
are required. See Figure 18.
The 7/8" rubber grommet is used to seal the opening
between the furnace cabinet and the gas pipe. The rubber
grommet should be installed in the 1 5/8" hole prior to
running the gas pipe into the cabinet. No sealants are
required.
The 3/4" rubber grommet is used if venting out the left
side of the cabinet and the drain tube is routed through
the blower deck. Remove the plastic plug from the hole
and install the grommet before routing the drain tube.
PVC TEE
Reducer&
HoseBarbs
The 2" PVC tee, reducer, and hose barb are used when
the inducer is rotated to vent out thru the left or right side
of the furnace cabinet. See Figure 19.
The 1/2" x 3/4" hose barb can be used to route the
condensate drain to the outside of the cabinet. It must
be installed from inside the cabinet with the threaded
end inserted
thru the 1 1/16" hole. See Figure 29
(page 33) for hole location The condensate drain should
be connected to the barbed end. Attach 1" PVC drain line
to the threaded end.
IMPORTANT NOTES:
= Before
permanently
installing these components,
it is recommended
you dry-fit them first to ensure
proper fit and alignment
with other vent pipes.
= The 2" PVC pipe shown in Figure 19 is not provided
in the extra parts bag.
1. Install the 1/2"x 1/2" hose barb on the 2" PVC reducer.
Do not over tighten! NOTE: Use an adequate amount of
Teflon tape on the threads. Do not use liquid sealants.
2. Install the reducer on one end of the PVC tee. Use
appropriate primer and cement to permanently bond
the reducer and tee together.
3. Install the tee on the 2" vent pipe that is extending out
the side of the cabinet. Use appropriate primer and
cement to permanently bond them together.
4. Verify all connections and joints for tight fit and proper
alignment with other vent pipes.
Finish Flange
Flange Gasket_
/
/
/
/
/
j_
..........
_
_---J
Figure 17. Finish Flange
_'_
_e2
1/4" Rubber
Grommet
O 3/4" Rubber
Grommet
7/8" Rubber
Grommet
Figure 18. Rubber Grommets
2" PVC Pipe from
Inline Drain Assembly
(Not Included)
Figure 19. PVC Tee (2"), Reducer & Hose Barb