Siemens C500 User Manual page 75

Microcontroller family
Table of Contents

Advertisement

MOV
direct, @ Ri
Operation:
MOV
(direct) ¬ ((Ri))
Encoding:
1 0 0 0
Bytes:
2
Cycles:
2
MOV
direct, #data
Operation:
MOV
(direct) ¬ #data
Encoding:
0 1 1 1
Bytes:
3
Cycles:
2
MOV
@ Ri,A
Operation:
MOV
((Ri)) ¬ (A)
Encoding:
1 1 1 1
Bytes:
1
Cycles:
1
MOV
@ Ri,direct
Ooeration:
MOV
((Ri)) ¬ (direct)
Encoding:
1 0 1 0
Bytes:
2
Cycles:
2
Semiconductor Group
0 1 1 i
direct address
0 1 0 1
direct address
0 1 1 i
0 1 1 i
direct address
4-49