Pioneer f-502 Service Manual page 10

Table of Contents

Advertisement

(4/4)
SI-PG06003-A
PDP436PU, PDP506PU,
PRO436PU, PRO506PU
G6
PDP425CMX
PDP6100HD, PRO1410HD,
NA
PDP614MX, PDP424MV
NA PDP4214HD, PDP42A3HD These models do not have Hours and P count meters.
Table 1
Service factory mode: In standby mode, press and
release "Display" key, wait for 4 sec then press and
release "Left", "Up", "Left", "Right", "Power" keys within
6 sec. Press "MUTING" key 3X -->
FACTORY" screen
---> Press "ENTER"---> Press"
DOWN" key 1X ---> Record the numbers.
guide should be turned off before entering service
mode.
Factory mode: In standby mode, press and release
"Display" key, wait for 4 sec then press and release
"Left", "Up", "Left", "Right", "Power" keys within 6 sec.
Press "DOWN" key 1X -->
Record the numbers.
Service factory mode: While TV is on, Press and
release "Power on", "Power on", "Exit", "Display" keys.
Press "EXIT" key 2X --->
screen
---> Record the hour number ----> Press
"POWER ON, POWER ON, EXIT, DISPLAY" keys to
Note: P ON COUNTER does not apply to these
exit.
models
"PANEL
Note: TV
"PANEL WORKS"
screen.
"MONITOR INFORMATION"
10
PANEL FACT.
ARA-30602-DIG-AH
PANEL WORKS
PM-B1
00001108 M
PM-B2
00001216 M
....
HR-MTR
000024H 29M
P-COUNT
00000103 TIMES
PANEL FACT.
ARA-30602-DIG-AH
PANEL WORKS
PM-B1
00001108 M
PM-B2
00001216 M
....
HR-MTR
000024H 29M
P-COUNT
00000103 TIMES
MONITOR INFORMATION
MODEL NAME
SERIAL NUMBER
SOFTWARE VERSION
USAGE TIME
00161 H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro-506pu

Table of Contents