Mechanical Instructions; Rear Cover Removal; Service Position Main Panel - Philips L01.1E Service Manual

Table of Contents

Advertisement

4. Mechanical Instructions

Note: Figures below can deviate slightly from the actual
situation, due to the different set executions.
4.1

Rear Cover Removal

1. Remove all (nine) fixation screws of the rear cover: two
at the top, two at each side, two at the bottom and one at
the SCART connectors.
2. Now pull the rear cover backward to remove it.
4.2

Service Position Main Panel

There are 2 configurations: one without and one with panel
bracket. Both have a different service position.
Main panel without bracket.
1. Disconnect the strain relief of the Mains cord.
2. Remove the main panel, by pushing the two centre clips
outward [1]. At the same time pull the panel away from
the CRT [2].
3. Disconnect the degaussing coil by removing the cable
from (red) connector 0201.
4. Turn the panel 90 degrees counter clockwise [3].
5. Flip the panel 90 degrees [4], with the components
towards the CRT.
6. Turn the panel with the rear I/O towards the CRT [5].
7. Slide the metal heatsink (near the mains transformer
5520) underneath the right chassis bracket, so the panel
is secured [6].
A
2
3
4
B
Figure 4-1
Mechanical Instructions
1
1
1
5
6
CL 16532016_007.ai
Main panel with bracket.
1. Disconnect the strain relief of the Mains cord.
2. Disconnect the degaussing coil by removing the cable
from (red) connector 0201 [1].
3. Remove the panel bracket from the bottom tray, by
pulling it backward [2].
4. Turn the chassis tray 90 degrees counter clockwise.
5. Move the panel somewhat to the left and flip it 90
degrees [3], with the components towards the CRT.
6. Turn the panel with the rear I/O towards the CRT.
7. Place the hook of the tray in the fixation hole of the
cabinet bottom [4] and secure it.
2
040401
L01.1E
4.
1
A
3
4
CL 16532016_009.eps
B
Figure 4-2
GB 11
220501

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents