Fujitsu MCE3064SS Product Manual page 128

Table of Contents

Advertisement

No.
Name
6
Bus Settle Delay
7
Cable Skew
Delay
8
Data release
Delay
9
Deskew Delay
10
Hold Time
11
Negation Period
12
Power-On to
Selection Time
13
Reset to Selection
Time
14
Reset Hold Time
15
Selection Abort
Time
16
Selection
Timeout Delay
Standard
400 ns min.
Minimum wait period between the time a particular
control signal condition changes and the time the
bus condition is stabilized.
10 ns max.
Maximum allowable difference in transmission time
over the interface cable between any two bus signals
from any two SCSI devices.
400 ns max.
Maximum allowable period between the time an I/O
signal changes its status from false to true and the
time the INIT stops driving data bus signals.
45 ns min.
Time for compensation for skew involved in bus
signal transmission.
45 ns min.
In synchronous data transfer mode, the minimum
time during which the transfer data on the DATA
BUS from the leading edge of the REQ or ACK
signal pulse must be maintained to compensate for
the hold time in the SCSI device receiving data.
90 ns min.
In synchronous data transfer mode, the minimum
time from the trailing edge of an REQ signal to the
leading edge of the next REQ signal,, or from the
trailing edge of an ACK signal to the leading edge of
the next ACK signal.
10 sec max.
Maximum time from when the TARG is turned on to
the time the TARG can post the correct status and
sense data for the TEST UNIT READY, INQUIRY
or REQUEST SENSE command.
250 ms max.
Maximum time from when the RESET condition
(hard RESET) is released to the time the TARG can
post the correct status and sense data for the TEST
UNIT READY,, INQUIRY or REQUEST SENSE
command.
25µs min.
The minimum time during which the RST signal
must be held true to create a RESET condition. A
maximum time is not defined.
200µs max.
In a SELECTION or RESELECTION phase,, the
maximum allowable period between the time the
SCSI device recognizes itself as selected and the
time it replies with a BSY signal.
250 ms min.
In a SELECTION or RESELECTION phase,, the
[Recommended
minimum time during which the INIT or TARG
value]
waits for a BSY signal from the SCSI device to be
selected before it initiates timeout processing.
C156-E097-01EN
Timing specification
7 - 11