Section 4 • Repair Procedures
GROUND CONTROLS
2-5

Outrigger Calibration

The Electronic Control Module (ECM) is
programmed to deactivate the drive and steer
functions while the outriggers are deployed and
activate an alarm when a signal is received from
the outrigger level sensor, indicating the outriggers
are not deployed or the machine is out of level.
The ECM is also used to calibrate the outrigger
level sensor to achieve a levelness of 0°
front to back and side to side, while the outriggers
are deployed.
For further information or assistance, consult the
Genie Industries Service Department.
How to Calibrate the Outrigger
System
1 Move the machine to a firm level surface that
is free of obstructions. Use a digital level to
confirm.
2 Turn the key switch to ground control.
3 At the ground controls, press and hold the
Menu Up and Menu Down buttons.
4 While pressing both buttons down, pull out the
red Emergency Stop Button.
5 Release the Menu Up and Menu Down buttons
after the ground controller powers up.
6 Use the Menu Up or Menu Down buttons to
scroll to Machine Options.
7 Press the Enter button to select Machine
Options.
8 Use the Menu Up or Menu Down buttons to
scroll to Outriggers.
9 Press the Enter button to select Outriggers.
4 - 14
10 Use the Menu Up or Menu Down buttons to
scroll to Calibrate Outriggers.
11 Press the Enter button to select Calibrate
Outriggers.
12 Press and hold the Enter button while the
system gathers data to calibrate the outrigger
level sensor.
+
/- 0.5°
13 Continue holding the Enter button after the
outrigger level sensor is calibrated. The
outriggers will retract while the outrigger system
gathers and saves data.
14 Continue holding the Enter button after the
outriggers retract. The outriggers will now
extend and the system will gather and save
data to calibrate the outriggers.
15 Continue holding the Enter button after the
outriggers extend. The outriggers will now
retract while the outrigger system gathers and
saves data.
Result: The alarms at the ground and platform
controls should sound for 1 second. The
outrigger system is calibrated.
Note: After installing a new outrigger level sensor,
the new outrigger level sensor must be calibrated
following this procedure.
GS-30 • GS-32 • GS-46 • GS-47
January 2012
Crushing hazard. Keep body parts
away from outriggers during
outrigger movement.
Part No. 228901