ELECTRICAL FEEDER CABLE REPLACEMENT
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorized service agent in order to avoid a hazard.
To connect the supply cable:
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
6.2).
•
Open the cable gland by unscrewing screw "F" (fig. 6.3), unscrew the terminal screws
and remove the cable.
•
The new supply cable, of suitable type and section, must be connected to the terminal
board following the diagram in fig. 6.4.
•
Close and hook again the terminal board cover.
NOTE: The earth conductor must be left about 3 cm longer than the others.
POWER SUPPLY
220-240 V
SECTION OF THE SUPPLY CABLE
TYPE "H05V2V2-F"
resistant to temperatures of 90°C
3 x 0,75 mm
2
F
34
50/60 Hz
1,1 W
Fig. 6.3
A
L
1
E
N (L
)
2
Fig. 6.2