9. TECHNICAL DATA

Power Connection
Voltage ................................................................... 230-240 V-AC
Current ......................................................................... 1~50 Hz
Connected/Load ............................................................. 2.0 KW
Mains Fuse ...................................................................... 13 AMP
Water Connection
Supply Temperature (Max) ............................................. 60 °C
Supply Rate (Min) ............................................................. 9 litres per minute
Supply Pressure (Max) ............................... (12 bar) ..... 1,2 MPa
Supply Hose Length ....................................................... 7.5 metres
Diameter ................................................... 1/2 inch
Performance Data
Pump Pressure (Max at bypass) ............. (130 bar) ...... 13 MPa
Operating Pressure .................................. (120 bar) ...... 12 MPa
Flow Rate ................................................. (450 l/h) ...... 7,5 litres per minute
Detergent Intake ............................................................. 0,4 litres per minute
Recoil Force of Spray Gun at Max. Pressure ................. 10 N
Optimum Working Distance on High Pressure ............... 30 cm
Hand-transmitted vibration (ISO 5349) .......................... 0,8 m/s²
Sound pressure level L
(EN 60704-1) .......................... 74 dB(A)
PA
Sound power level L
(2000/14/EC) .............................. 96 dB(A)
WA
Dimensions
Length ............................................................................ 510 mm
Width .............................................................................. 255 mm
Height ............................................................................ 285 mm
Weight ............................................................................. 14 Kg
Circuit Diagram
C1 Running capacitor
F1
Temperature fuse
M1 Motor
S1 Appliance switch
S2 Pressure-operated switch