REMOTE CONTROLS - GENERAL
n When deciding on the best positions for the Remote Controls, the following points
should be taken into consideration.
1. Fit the Controls
out of reach of children.
(Suggested
height from floor -
1500mm).
2. Avoid positions where the Remote Control will become hot (eg: over hotplates,
near ovens or heaters).
3. If possible, avoid direct sunlight (The Digital Monitor is difficult to read in direct
sunlight).
4. Avoid areas where Remote Control will be affected by oil splashing
or cooking.
5. The BC-31-A
Master Control
is water resistant,
however
it should
not be
positioned
where it may be splashed
directly
(ie: shower recess).
6. Refer to AS3000
1986 Section 6.3. for location
requirements
in shower and
bath areas.
7. The cables to the Remote Controls only carry 12vDC (extra low voltage).
8. Cables should run back to the Infinity 20 from both RemoteControls,
or cables
should run between the Controls
then back to the Infinity 20.
Possrb\e cable arrangemen&
are shown below.
Control
Master
Control
Sub
Control
Master
Control
Both Controls are equal
Master Control is closer to
distance from Infinity 20.
Infinity 20 than Sub Control.
Sub Control is closer to
Infinity 20 than Master Control.
Cables are simply piggy-backed
at either the Infinity 20 or Remote Control. Polarity
is not important when connecting
Controls. Either colour wire can be connected to
either terminal at both the Infinity 20 and Control terminals. If more cable is needed
any cable with a similar specification
to the cable supplied with the Infinity 20 can
be used. Maximum
length is 50m.
-14-