3
WR-210AE
CONNECTIONS

Connectable PA Systems

Refer to the following table to determine the number of Remote Microphones that can be connected to the PA systems.
PA System Name
Name
Type
Mixing Power Amplifier
WA-MA120N
WA-MA240N
*A maximum of 4 Remote Microphones can be connected to each WR-210AE.

Cable Diameters

Cable Lengths
200 m or less
Shielded cable
0.5 mm
2
(AWG20) to 1.25 mm
Control cable
ø0.8 mm (AWG20) to
ø1.2 mm (AWG16)
• If cables other than those shown above are used, use a cable with 1-wire line
resistance that is not in excess of 7 Ω.
• If you plan to move the Remote Microphone while using it, use a stranded
conductor cable to extend it.
Depending on the PA system being used, the shielded cable connected to the LINE OUT terminal should be either shielded
mono cable or shielded pair cable.
PA System Name
Mixing Power Amplifier
LINE INPUT Terminal and REC OUT Terminal Connection
Connect the pin plug's signal wire and GND wires to the ø6.3 monaural plug's tip contact and sleeve contact respectively.
When a ø6.3 stereo plug is used, the connection method is shown below.
H
C
36
Number of devices that can be connected
Remote Microphone (WR-210AE)
Extension Unit (WU-RM205E)
4
4*
4
4*
500 m or less
2
(AWG16)
ø1.2 mm (AWG16)
11 mm
Cable Type
Shielded pair cable
Mixing Power Amplifier (WA-MA120N/240N) Connection
Move the -22 dBV(RM)/-65 dBV switch on the Mixing Power Amplifier to the -22 dBV(RM) side.
C
WR-210AE
10 9
8
7
6
5
4
3
2
Note 2
Note 1
WA-MA120N
or
WA-MA240N
Note 1:
Connect to play the Mixing Power Amplifier's call sign from the CALL SIGN button on the Remote Microphone.
Note 2:
To perform 2-channel announcement from the Remote Microphone, connect the CALL terminal to any one of the C4 to C10 terminals
of the Remote Microphone. The numbered switch (4-10) on the Remote Microphone that corresponds to the terminal number you
connect to can be used to switch to zone 1 interrupt during 2-channel announcement.
*1: Connect to a C terminal to make 2-channel announcements from the Remote Microphone. The number to which the connection was made is
the number of the switch for the 2-channel announcements.
CONNECTIONS
WR-210AE
CALL SIGN
PRIORITY
LINE OUT
COM
DC
CKO
CONT
0V
(0V)
24V
1
DOWN
UP
OUT IN
C H
*1
3
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents