Figure 6 Removing a p1224 card, example shows an HPE StoreOnce 4700 Backup
4.
Install the new p1224 card (1) and check that it is seated properly. Close the blue PCIe card
retaining latch (2).
Figure 7 Inserting a p1224 card, example shows an HPE StoreOnce 4700 Backup
5.
Make sure the card is connected to the SuperCapacitor module and to the internal and
external SAS data storage.
6.
Replace the cover, as described in the appropriate HPE ProLiant Maintenance and Service
guide, and power on the HPE StoreOnce Backup system.
7.
Once rebooted, the HPE StoreOnce Backup system will identify the new RAID controller
and will remap the existing disk storage volumes and enclosures to the controller. It will take
5 to 10 minutes for the process to complete. During this time the product will be online but
several warning events will be generated and the GUI Hardware Report will show errors
being reported and cleared.
8.
Use the StoreOnce GUI or StoreOnce CLI to check that the firmware on the new component
is correct. See
Upgrading BIOS or hardware firmware (page
NOTE:
The system reboots after a firmware upgrade, but for some components a cold
reboot is required to complete the process. A message is displayed after the reboot if a cold
reboot is also required. Power down the system, wait the time recommended in the message
and then power on again using the Power On button.
13).
Replacing the HP p1224 controller
27