HP StorageWorks director 2/64 Installation Instructions Manual
HP StorageWorks director 2/64 Installation Instructions Manual

HP StorageWorks director 2/64 Installation Instructions Manual

Universal port module kit

Advertisement

Quick Links

hp StorageWorks
universal port module kit
installation instructions
Part Number: AA–RSS2B–TE/958-000281-000
Second Edition (November 2002)
These installation instructions provide procedures for setting up,
configuring, and managing a UPM kit in an HP StorageWorks
Director 2/64 or a Director 2/140.

Advertisement

Table of Contents
loading

Summary of Contents for HP StorageWorks director 2/64

  • Page 1 StorageWorks universal port module kit installation instructions Part Number: AA–RSS2B–TE/958-000281-000 Second Edition (November 2002) These installation instructions provide procedures for setting up, configuring, and managing a UPM kit in an HP StorageWorks Director 2/64 or a Director 2/140.
  • Page 2 © Hewlett-Packard Company, 2002. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 3: Table Of Contents

    HP Technical Support ........
  • Page 5: About This Guide

    Test the UPM kit for proper operation. • Contact technical support for additional assistance. Intended Audience This book is intended for use by owners of the hp StorageWorks director 2/64 or the director 2/140. Document Conventions The conventions included in Table 1 apply.
  • Page 6: Symbols In Text

    About this Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or data.
  • Page 7: Rack Stability

    About this Guide Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. Contact with this surface could result in injury. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
  • Page 8: Getting Help

    Operating system type and revision level • Detailed, specific questions HP Website The HP website has the latest information on this product, as well as the latest drivers. http://thenew.hp.com/country/us/eng/prodserv/storage.html. Access storage at: From this website, select the appropriate product or solution.
  • Page 9: Installation Instructions

    Install the UPM Supported Kits HP sells the StorageWorks Director 2/64 with a base configuration of 32 Fibre Channel ports and the StorageWorks Director 2/140 with a base configuration of 64 Fibre Channel ports. HP also sells optional kits to increase the number of ports to a maximum of 64 for the Director 2/64 and a maximum of 140 for the Director 2/140.
  • Page 10: Installing The Upm

    Installation Instructions Installing the UPM This section describes procedures to install one UPM card, even though you can install more than one UPM card at the same time. If you are installing more than one UPM card, ensure that the procedure steps are applied to all UPM cards being installed.
  • Page 11 Installation Instructions NOTE: Figure 1 shows a cable management assembly for the Director 2/64 that is only used with the 9000, 10000, and 11000 Series cabinets. NOTE: For the Director 2/64, rotate the cable management assembly, if used, to reach the grounding point.
  • Page 12 Installation Instructions Figure 2: Director 2/140 ESD grounding points As shown in Figure 2, the ESD grounding point for the rear of the Director 2/140 chassis is located next to the maintenance port. As shown in Figure 3, the ESD grounding point for the rear of the Director 2/64 chassis is located at the bottom center, directly below the maintenance port.
  • Page 13: Removing The Upm Filler Blank

    Installation Instructions Touch the chassis once before performing any maintenance action, and once each minute while installing UPMs. SHR 2300 ESD Grounding Point Figure 3: ESD grounding point (rear) Removing the UPM Filler Blank Use the following procedure to remove a UPM filler blank. Filler blanks cover and protect unused UPM card slots in the director chassis.
  • Page 14 Installation Instructions 3. Insert the torque tool into each locking Allen screw, as shown in Figure 4 for the Director 2/64 and Figure 5 for the Director 2/140. Turn each screw counter-clockwise until the spring releases and the tool turns freely. UPM Filler Blank Torque Tool Figure 4: Director 2/64 UPM filler blank removal...
  • Page 15: Installing The Upm Card

    Installation Instructions Figure 5: Director 2/140 UPM filler blank removal 4. Pull the filler blank out and remove it from the director chassis. Installing the UPM Card Use the following procedures to install a UPM card. A list of required tools is provided.
  • Page 16: Installation

    Installation Instructions Installation 1. Follow ESD procedures by attaching a wrist strap to the director chassis. CAUTION: To avoid causing machine errors or damage while working on the director, follow ESD procedures by connecting a grounding cable to the director chassis and wearing an ESD wrist strap.
  • Page 17 Installation Instructions Figure 7: Director 2/140 UPM card installation 2. Remove the UPM card from its protective anti-static bag. 3. Hold the card by its stiffener and insert it in the chassis card track, as shown in Figure 6 for the Director 2/64 and Figure 7 for the Director 2/140.
  • Page 18 Do not use an Allen wrench or torque tool designed for use with another HP or Compaq product. Use of the wrong tool may overtighten and damage logic cards.
  • Page 19: Miscellaneous Procedures

    Verify UPM card information (FRU name, position, and state) is correct. If a problem is indicated, go to MAP 0000: Start MAP of the hp StorageWorks director 2/64 service manual to isolate the problem. 12. Close and lock the equipment cabinet door.
  • Page 20 Installation Instructions 4. At the Hardware View, verify the location of the port or UPM card to be tested. When the mouse cursor is passed over a graphical UPM card on the front view of the director, the card highlights with a blue border and a pop-up displays with the following information: —...
  • Page 21 Installation Instructions Figure 8: Port Diagnostics dialog box 9. Select a port or UPM card for test, perform one of the following: — To select an individual port for test, type the port number in the Port Number field. — To select a UPM card for test, type the port number of any of the four ports an the card in the Port Number field, then choose All Ports On Card.
  • Page 22 Installation Instructions 12. Verify loopback plug(s) are installed and click Next. The following message displays: Verify selected ports are beaconing. 13. Verify beaconing is enabled, then click Next. The following message displays: Press START TEST to begin diagnostics. The Next button changes to Start Test. 14.
  • Page 23: Unblocking A Upm Card

    Installation Instructions Unblocking a UPM Card To unblock all four ports on a director UPM card: 1. Open the ha-fabric manager application and log in. The Product View displays. 2. Double-click the director icon for which the UPM card will be unblocked. The Hardware View displays.