Bridge Mode Hi-Z (140Vrms/200Vrms)

Typical input and output wiring, along with software
settings are shown in Figure 27 and Figure 28.
INPUTS: Connect the input to the odd-numbered
channels (1,3,5,7) only. Even-numbered inputs are
disabled when the Bridge Mono mode is active.
OUTPUTS: Connect the speaker across the positive
terminals of each channel pair. Do not use the
negative terminals of the channel pair when the pair
is being operated in Bridge Mono mode.
NOTE: For global selection of 70Vrms (140Vrms
bridged) or 100Vrms (200Vrms bridged) operation,
refer to "Hi-Z/Low-Z" on page 15.
DANTE: When connecting via Dante, two Dante-
equipped devices can be connected directly together
using the Primary Dante ports. If connecting more
than two Dante devices, the Primary ports of each device should be connected to a network switch (this is a referred to as a "star" network topology).
100Mbps network switches and Category 5 cabling can be used for smaller Dante networks where smaller channel counts and/or lower sample rates are used. For optimum
performance and improved reliability, a Gigabit network and Category 5e or Category 6 cabling should be used. Visit the Audinate website for more information.
To provide fault protection when using Dante, connect the Secondary ports of all Dante devices to a secondary (separate) network switch. If any "primary" cable connections
or the "primary" switch fail, the "secondary" Dante network will automatically take over.
For further information on Dante, refer to "Dante" on page 28.
NOTE: Always route the input and output wires in separate bundles.
WARNING: Only connect to networks that remain inside the building.
DriveCore Install DA Series Operation Manual
RESET
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
100 – 240V
50/60 Hz 1400W
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
Figure 27: System wiring for 140Vrms/200Vrms operation
Figure 28: Audio Architect amplifier mode settings
ETHERNET
GPIO
ACT
100Mb
+3.3V
DANTE
PRIMARY
SECONDARY
OUT
DATA
PRESET
IN
BRIDGE
OUTPUT
DUAL
DUAL
CLASS 2
MAC
WIRING
WIRING
ADDRESS
2
1
4
3
2
1