MENU
PICTURE
POSITION
ADVANCED MENU
LANGUAGE
OPTION1
OPTI0N2
TEST PATTERN
SYSTEM INFORMATION
ROM VERSION
1. 00. 00
SET RUNTIME
300h
LAMP1 LOW
100h
HIGH
200h
TOTAL
300h
LAMP2 LOW
100h
LAMP TIME RESET
LAMP1
LAD55
1433h
LAD55L
0h
LAMP2
LAD55
1100h
LAD55L
0h
Insert the power cord plug into the wall outlet and then
press the MAIN POWER switch.
• If the power does not turn on even after turning the MAIN
Attention
POWER switch "I", turn the MAIN POWER "O", confirm that
the lamp unit and door are installed correctly, and turn on
again.
Press the " I " button so that a picture is projected onto
the screen.
Press the "MENU" button to display the MAIN MENU
screen, and then press the
the cursor to select "OPTION2".
Press the "ENTER" button to display the "OPTION2"
screen, and select "SYSTEM INFORMATION" with the
and
buttons.
Press the "ENTER" button.
The SYSTEM INFORMATION screen will be displayed.
Press and hold the "ENTER" button on the projector or
the remote control for approximately 3 seconds.
An item "LAMP TIME RESET" will be added.
Select the lamp which has been replaced with the
buttons.
LAMP1: Replace the LAMP UNIT 1
LAMP2: Replace the LAMP UNIT 2
Press the ENTER button, and when the "LAMP TIME
RESET" display flashes, press the ENTER button again.
The used hours of the specified lamp unit will be reset to zero.
When more than one lamp has been replaced, repeat the procedure from
step
.
• When the "LAMP TIME RESET" display flashes, the lamp
Note
time reset can be canceled by pressing the MENU button.
• The used hours of the lamp units can also be reset to zero
by taking the following action instead of steps
When lamp unit 1 has been replaced:
In the standby mode, press the number buttons in the
sequence of 737381, and then press the ENTER button.
When lamp unit 2 has been replaced:
In the standby mode, press the number buttons in the
sequence of 737382, and then press the ENTER button.
When the used hours have been reset, the lamp monitor
(LAMP1/LAMP2) will flash for 3 seconds.
and
buttons to move
to
and
.
45