SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

5-1-1 CONVENTIONAL VERSION
When you adjust the contents on pages 5-7 to 5-9, SOFTWARE ADJUSTMENT, the optional CS-F30G ADJ
(Rev. 1.0 or later), *OPC-966
WARE
I REQUIRED TEST EQUIPMENT
EQUIPMENT
Output voltage
DC power supply
Current capacity
Frequency range
FM deviation meter
Measuring range
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Sensitivity
Digital multimeter
Input impedance
Measuring range
RF power meter
Frequency range
(terminated type)
Impedance
SWR
I SYSTEM REQUIREMENTS
• IBM PC compatible computer with an RS -232C serial port
(38400 bps or faster).
• Microsoft Windows 95 or Windows 98
• Intel i486DX processor or faster (Pentium 100 MHz or
faster recommended)
• At least 16 MB RAM and 10 MB of hard disk space
• 640×480 pixel display (800×600 pixel display recommend-
ed)
I ADJUSTMENT SOFTWARE INSTALLATION
q Boot up Windows.
- Quit all applications when Windows is running.
w Insert the 'CS-F30G' into the appropriate drive.
e Select 'Run' from the [Start] menu.
r Type the setup program name using the full path name,
then push [Enter] key.
(ex. D:\CSF30GADJ\disk1\Setup.exe)
t Follow the prompts.
y Program group 'CS-F30G ADJ' appears in the 'Programs'
folder of the [Start] menu.
I STARTING SOFTWARE ADJUSTMENT
q Connect IC-F40GT, F40GS, F41GT or F41GS and PC
with *OPC-966
JIG CABLE
w Turn the transceiver power ON.
e Boot up Windows, and click the program group 'CS-F30G
ADJ' in the 'Programs' folder of the [Start] menu, then
CS-F30G ADJ's window appears.
r Click 'Connect' on the CS-F30G's window, then appears
IC-F40GT, F40GS, F41GT or F41GS's up-to-date condi-
tion.
t Set or modify adjustment data as desired.
(modified OPC-966
JIG CABLE
GRADE AND RANGE
: 7.5 V DC
: 5 A or more
: DC–600 MHz
: 0 to ±10 kHz
: 0.1–600 MHz
: 100 mV or better
: 10 MΩ/V DC or better
: 1–10 W
: 300–600 MHz
: 50 Ω
: Less than 1.2 : 1
.
) are required.
CLONING CABLE
EQUIPMENT
Frequency range
Audio generator
Output level
Power attenuation
Attenuator
Capacity
Frequency range
Standard signal
Output level
generator (SSG)
DC voltmeter
Input impedance
Frequency range
Oscilloscope
Measuring range
AC millivoltmeter
Measuring range
• High power transmittion
When you adjust the output power (high power), the battery
type detector must be connected to GND (see illustration at
below). Otherwise the transceiver does not transmit high
power, the output power will be low.
Battery type detector
Battery type detector
IBM is a registered trademark of International Bussiness
Machines Corporation in the U.S.A. and other countries.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
Screen shots produced with permission from Microsoft
Corporation. All other products or brands are registered
trademarks or trademarks of their respective holders.
5 - 1
ADJUSTMENT SOFT-
GRADE AND RANGE
: 300–3000 Hz
: 1–500 mV
: 40 or 50 dB
: 10 W or more
: 300–600 MHz
: 0.1 µV–32 mV
(–127 to –17 dBm)
: 50 kΩ/V DC or better
: DC–20 MHz
: 0.01–20 V
: 10 mV–10 V
+
DC power supply
7.5 V/5.0 A
Connect to GND