Trane TCONT402AN32DA Installer's Manual page 6

Electronic non-programmable 3 heat (gas, oil or elec) / 2 cool / heat pump, dual fuel
Hide thumbs Also See for TCONT402AN32DA:
Table of Contents

Advertisement

DUAL FUEL SINGLE STAGE HEAT PUMP
NON-VARIABLE SPEED ONE OR TWO STAGE GAS FURNACE
BK DISABLED
Note C - For Dual Fuel, cut the JP1 jumper on the Comfort Control.
NOTE: See Fig. OIL-1 for external relay connections for oil furnaces.
COMFORT CONTROL
NON-V.S. ONE
Y2
OR TWO STAGE
GAS FURNACE
W3
24VAC HOT
R
HEATING -
W2
W2
3rd STAGE
W/
HEATING -
W1
2nd STAGE
W1
COOL/HEAT -
Y/
1st STAGE
Y1
G
FAN
SOV
O
B
B
24VAC
common
BK
O D Temp
OT1
O D
Sensor
O D Temp
OT2
Figure DF-5
6
SINGLE STAGE
HEAT PUMP
R
R
X2
Y
Y
G
O
B
C
T
JP 1 Location
Installer's Guide
Pub. No. 18-HD29D3-4
JP1
Cut for
Dual Fuel
Applications

Hide quick links:

Advertisement

Table of Contents
loading