Trane TCONT402AN32DA Installer's Manual page 13

Electronic non-programmable 3 heat (gas, oil or elec) / 2 cool / heat pump, dual fuel
Hide thumbs Also See for TCONT402AN32DA:
Table of Contents

Advertisement

TABLE 3A
USER SETUP (USU)
Press and hold MODE and FAN at the same time.
Menu Item
Temperature Display
Auto or Manual Changeover
Setpoint Deadband
Waiting Icon
Cooling Droop
Energy Savings -
Cooling Setpoint Offset
Energy Savings -
Heating Setpoint Offset
Indoor Filter Timer Method
Indoor Filter Reminder - Days
Calibrate Indoor Temperature
Calibrate Outdoor Temperature
Calibrate Remote
Indoor Temperature
Continous Fan Airflow
Exit User Setup
(Press Mode)
Note: Pressing Energy Saving Key ($) anytime during setup will
advance to "Step 99"
Step 99 - Make setting selection and then press MODE to exit.
SA = SAves all current settings. Press MODE to exit.
CA = CAncels the current settings. Press MODE to exit.
FA = Resets all settings to FActory defaults and clears history and
service data from the EEPROM. Press MODE to restore
defaults and return to step 1 of Installer setup menu.
CL = CLears all history and service data counts. Press MODE to
clear all history and service data from EEPROM and return to
step 1 of installer setup menu.
CS = Clears Setup to Installer (steps 1 - 49) and User (steps 50 -
69) settings. Installer settings shall be restored to factory
settings and User settings shall be restored to defaults. Press
MODE to save selections and return to step 1 of Installer setup
menu.
US = Restores the USer default settings. Press MODE to exit.
Note: The User (US) exit option in the User menu will not restore
Installer settings.
Steps 16 & 18: With BK Output disabled, do not select a Comfort
Control Blower On-Delay if an Enhanced (Comfort-R) airflow
profile is selected at the variable speed indoor unit.
Steps 17 & 19: With BK Output disabled, do not select a Comfort
Control Blower Off-Delay if a blower off delay is selected at the
indoor unit.
Step 5 System Type = 1 (AC): Steps 15, 18-19, 24-27, 41-49 not
available.
Step 5 = 1 and Step 6 = 1 (1C): Step 35 not available.
Step 5 = 2 and Step 6 = 1 and Step 9 = 0 (1H/1C HP): Steps 35, 45
not available.
Pub. No. 18-HD29D3-4
Default
Setting (Choices)
(Press UP or DOWN arrow)
0
0=Fahrenheit,1=Celsius
1
0=Manual,1=Auto
3
2 - 10 Degrees Fahrenheit
1.5 - 5.0 Degrees Celsius
1
0=Disable,1=Enable
1
0 = Off
1 = 1 Degree
2 = 2 Degrees
5
0 - 25 Degrees Fahrenheit
0 - 15 Degrees Celsius
5
0 - 45 Degrees Fahrenheit
0 - 25 Degrees Celsius
0
0=Calender Days,1=Fan RunTime
Days
30
1-180 Days,0=Disabled
0
Calibrated Room Temperature
+ / - 5 Degrees (1/2 degree
increments)
0
Calibrated Outdoor Temperature
+ / - 5 Degrees (1/2 degree
increments)
0
Calibrated Room Indoor Temperature
+ / - 5 Degrees (1/2 degree
increments)
50%
35%-100%
SA
CA = Cancel
SA = Save
US = Default User Settings
Installer's Guide
Step
(Press
Mode or
Fan)
50
51
52
53
54
55
56
57
58
59
60
61
62
99
(Exit)
Step 5 = 1 and Step 9 = 0 (0H/1C): Steps 51-52 not available.
Step 5 = 2 and Step 8 = 1 (Dual Fuel): Step 47 not available.
Step 5 = 2 (HP): Step 6 (Compressor Stages) cannot be set to "0".
Changing Step 5 to "2" will force the settings for Steps 6, 8, and 9.
Step 6 Compressor Stages = 0 (None): Steps 7, 12-27, 35, 37, 40-
49, 51-52, 54 not available.
Step 6 Compressor Stages = 1 (Single Stage): Steps 7, 14, 22-23,
26-27 not available.
Step 6 Compressor Stages = 2 (Two Stage/Two Step): Step 40 not
available.
Step 8 Heater Type = 1 (Gas/Oil): Steps 38-39 not available.
Step 8 Heater Type = 2 (Electric): Steps 38-39 not available.
Step 8 Heater Type = 3 (Wet Heat): Steps 32-33, 49 not available.
Step 9 Heater Stages = 0 (None): Steps 28-33, 38-39, 43-44, 46-49
not available.
Step 9 Heater Stages = 1 (Single Stage): Steps 30-33, 48-49 not
available.
Step 9 Heater Stages = 2 (Two Stage): Steps 32-33, 49 not
available.
Step 10 Outdoor Sensor = 0 (None): Steps 40-49, 60 not available.
Step 10 Outdoor Sensor = 1 (Display Only): Steps 41-49 not
available.
Step 11 BK Output = 0 (BK Disabled): Steps 12-15, 40 not available.
Step 11 BK Output = 1 (BK Enabled): Steps 16-19 not available.
Step 36 Remote Indoor Sensor = 0 (None): Step 61 not available.
Step 43 HP Restricted Mode = "—": Step 44 not available.