Trane TCONT402AN32DA Installer's Manual page 12

Electronic non-programmable 3 heat (gas, oil or elec) / 2 cool / heat pump, dual fuel
Hide thumbs Also See for TCONT402AN32DA:
Table of Contents

Advertisement

Table 3
INSTALLER SETUP (ISU)
*see notes at the bottom of setup (ISU) Table 3A
1. Set System MODE to OFF
2. Set FAN to AUTO
3. Press and hold MODE and Up arrow at the same time.
Factory
Menu Item
Setting
Error Count
0
Software Version
Configuration
Signature - LoByte
Configuration
Signature - HiByte
System Type
1
Compressor Stages
2
Compressor Type
0
Indoor Heater Type
1
Indoor Heater Stages
2
Outdoor Sensor
0
BK Output
1
Variable Speed Blower
1
Turn-On Delay Profile
Variable Speed Blower
1
Turn-Off Delay Profile
65%
Compressor
Low Stage Airflow
50%
Heat Pump Warm Air Discharge
0
Non-Variable Speed
0
Cooling Blower ON delay
Non-Variable Speed
0
Cooling Blower OFF delay
Non-Variable Speed Compressor
0
Heating Blower ON delay
Non-Variable Speed Compressor
0
Heating Blower OFF delay
1st Stage Compressor
3
Cooling Cycles Per Hour
1st Stage Compressor Cooling
3
Minimum On Time
2nd Stage Compressor
3
Cooling Cycles Per Hour
2nd Stage Compressor Cooling
3
Minimum On Time
1st Stage Compressor
3
Heating Cycles Per Hour
1st Stage Compressor Heating
3
Minimum On Time
12
Step
Setting (Choices)
(Press
(Press UP or DOWN arrow)
Mode
Fan)
None
None
None
None
1=AC,2=HP
0=None
1=Single Stage
2=Two Stage/Two Step
0=Two Step, 1=Two Stage
1=Gas,Oil
2=Electric
3=Wet Heat
0=None
1=Single Stage Heater
2=Two Stage Heater
3=Three Stage Heater
0=None
1=Has Sensor for Display Only
2=Has Sensor for Display and for Control
0 = BK Disabled
1 = BK Enabled
1 = No Delay
2 = 1 Minute @ 50%, 7.5 Minutes @ 80%
3 = 1 Minute @ 50%, 4 Minutes @ 80%
4 = 7.5 Minutes @ 80%
5 = 4 Minutes @ 80%
6 = 1 Minute @ 50%
7 = 30 Second Delay
1 = No Delay
2 = 1.5 Minutes @ 100%
3 = 45 Seconds @ 100%
4 = 30 Seconds @ 50%
5 = 1.5 Minutes @ 50%
6 = 3 Minutes @ 50%
7 = 30 Seconds @ 35%
Two Step Range: 55%-80%
Two Stage Range: 35%-60%
0=Disabled,1=Enabled
0 - 30 Seconds
0 - 90 Seconds
0 - 30 Seconds
0 - 90 Seconds
2 - 6 CPH
1 - 15 Minutes
2 - 6 CPH
1 - 15 Minutes
2 - 6 CPH
1 - 15 Minutes
2nd Stage Compressor
Heating Cycles Per Hour
2nd Stage Compressor Heating
Minimum On Time
1st Stage Heater
Cycles Per Hour
1st Stage Heater
Minimum ON Time
1
2nd Stage Heater
Cycles Per Hour
2
2nd Stage Heater
3
Minimum ON Time
3rd Stage Heater
4
Cycles Per Hour
5
3rd Stage Heater Minimum ON Time
6
Control Response Rate
Aggressive Recovery Due To A
7
Setpoint Change > 2 Degrees F
Remote Indoor Sensor
8
Humidistat For Dehumidification
9
Wet Heat Blower ON Delay
Wet Heat Blower OFF Delay
10
Cooling Efficiency Booster - Single
Stage Compressor Only
11
Outdoor Sensor for Control -
Temperature Units (Steps 43-49)
12
Heat Pump Restricted Mode
Outdoor Temperature
Resume Heat Pump Operation
Outdoor Temperature
13
Heating Aggressive Recovery
Outdoor Temperature
14
15
Auxilliary Heat Lockout
Outdoor Temperature
16
17
W1 Heater Balance Point During
Defrost Outdoor Temperature
18
19
W2 Heater Balance Point During
Defrost Outdoor Temperature
20
21
W3 Heater Balance Point During
22
Defrost Outdoor Temperature
23
24
Exit Installer Setup
Press $ to advance to step 99
25
Installer's Guide
3
2 - 6 CPH
3
1 - 15 Minutes
3
2 - 6 CPH
3
1 - 15 Minutes
5
2 - 6 CPH
3
1 - 15 Minutes
5
2 - 6 CPH
3
1 - 15 Minutes
0
0=Normal, 1=Fast
0
0=Disabled,1=Enabled
0
0=None,1=Has Sensor
0
0=Disabled,1=Enabled
30
0 - 60 Seconds
30
0 - 90 Seconds
0
0=Disabled,1=Enabled
0
0=Fahrenheit,1=Celsius
"--"
"--" = Disabled
then
10 to 70 Degrees F
40
4.5
-12 to 21 Degrees C
"--"
"--" = Disabled
then
14 to 74 Degrees F
44
6.5
-10 to 23 Degrees C
"--"
"--" = Disabled
then
10 to 70 Degrees F
40
4.5
-12 to 21 Degrees C
"--"
"--" = Disabled
then
15 to 75 Degrees F
45
7
-9 to 24 Degrees C
"--"
"--" = Disabled
then
-10 to 55 Degrees F
55
13
-23 to 13 Degrees C
"--"
"--" = Disabled
then
-10 to 55 Degrees F
40
4.5
-23 to 13 Degrees C
"--"
"--" = Disabled
then
-10 to 55 Degrees F
25
-4
-23 to 13 Degrees C
SA = Save
CA = Cancel
SA
CL = Clears History and Service Data only
CS = Clears Setups
FA = Factory Default
Pub. No. 18-HD29D3-4
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
43
44
45
46
47
48
49
99
(Exit)

Hide quick links: