Removal Of The Gas Valve - Flavel Firenza FFIRR0MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

4.3
REMOVING THE GAS VALVE FROM THE FIRE
a)
Disconnect the appliance from the gas supply.
b)
Remove the case as described in section 4.11
c)
Disconnect the main pipe, inlet pipe & pilot pipe from the valve, then
remove the push fit thermocouple and ignition lead, as shown below in
fig. 9
Fig. 9
Main Pipe
d)
Remove the control valve locknut and lift clear.
Push Fit Thermocouple
17
Pilot Pipe
Ignition Lead
Inlet Pipe

Advertisement