Servicing Notes
Servicing should be carried out annually by a competent person such as a
Corgi registered engineer.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for positive up-draught in
the chimney.
The condition of the ceramic plaques should be checked and if necessary the
whole set should be replaced with a genuine replacement set.
After any servicing work a gas tightness test must always be carried out.
4.1

GENERAL ACCESS FOR SERVICING

4.1.1
TO REMOVE THE CASE
a)
Prepare work area (lay down dustsheets etc.), Disconnect the appliance
from the gas supply.
b)
Remove the two case rear fixing screws, see fig. 6 below
c)
Remove the radiants and move to a safe place
d)
Re-assemble in the reverse order.
Fig. 6
Removing the two case fixing screws