Hearth Fixing; Wall Mounting; Gas Connection - Flavel Firenza FFIRR0MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

2.3

HEARTH FIXING

With the closure plate fitted as described on page 10, loosen the locknuts on the
front feet. If a side gas connection is to be used, reverse the rear foot on that
side, to clear the supply pipe. Place the fire into position and adjust level by
rotating the feet, then re-tighten the locknuts.
2.4

WALL MOUNTING

There must be a minimum clearance of 130mm between the bottom of the case
and the floor. This is achieved by drilling the holes in the wall as shown below in
Fig. 4
Fig. 4
Drill and plug all four holes to take 2 inch No. 10 woodscrews, loosely insert the
screws, and place the closure plate in position, sealing it to the wall with 50mm
high temperature adhesive on all four sides. Remove the lower screws and screw
in the upper ones to leave a 7 to 8mm gap under the heads. Remove the fire feet.
Hang the fire on the upper screws, remove the lower screws and tighten all four
screws.
2.5

GAS CONNECTION

Note :
A means of isolation must be provided near to the appliance to facilitate
servicing.
Ensure that the gas supply is turned off before commencing.
The gas connection should be made to the appliance inlet elbow using 8 mm rigid
tubing. The gas connection can be made left hand, right hand or rear. In line with
current installation regulations, a restrictor should be fitted to the inlet pipework to
isolate the appliance for servicing and repair purposes.
Before making the final gas connection, thoroughly purge the gas supply
pipe work to remove all foreign matter, otherwise serious damage may be
caused to the gas control valve on the fire.
Closure Plate
Floor Level
11
650mm
Minimum